31455-10-1115
Page 64
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING
: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR
LOSS OF LIFE.
A. This appliance has a pilot which must be lighted with
the remote control. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING, smell around the appliance area for
JDV%HVXUHWRVPHOOQH[WWRWKHÀRRUEHFDXVHVRPHJDV
LQKHDYLHUWKDQDLUDQGZLOOVHWWOHRQWKHÀRRU
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electrical switch.
•
Do not use any phone in your building.
•
Immediately call your gas supplier from a
QHLJKERUV SKRQH )ROORZ WKH JDV VXSSOLHUV
instructions. If you can not reach your gas
VXSSOLHUFDOOWKH¿UHGHSDUWPHQW
C. Use only the remote control to operate the gas control
NQRE1HYHUXVHWRROV,IYDOYHGRHVQRWRSHUDWHGRQW
WU\WRUHSDLULWFDOODTXDOL¿HGVHUYLFHWHFKQLFLDQ)RUFH
RUDWWHPSWHGUHSDLUPD\UHVXOWLQD¿UHRUH[SORVLRQ
D. Do not use this appliance if any part has been under water.
,PPHGLDWHO\FDOODTXDOL¿HGVHUYLFHWHFKQLFLDQWRLQVSHFW
the appliance and to replace any part of the control system
and any gas control which has been under water.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
1.
Turn off all electric power to the appliance if service is to
be performed (if applicable).
2. Open bottom louver assembly.
3.
Locate On/Off gas cock and turn clockwise to
"OFF." Do not force.
4. Close bottom louver assembly.
RF STANDING PILOT LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Turn OFF electric power to the appliance.
3. Open bottom louver assembly.
4. Turn gas cock counterclockwise
to "ON"
position.
5.
Wait ten minutes to clear out any gas. Then smell for gas,
LQFOXGLQJQHDUWKHÀRRU,I\RXVPHOOJDV6723)ROORZ
"B" in the safety information above on this label. If you
do not smell gas, go to the next step.
6. Turn ON electric power to the appliance.
7. Find pilot - Follow metal tube from gas control. The pilot
is behind the burner on the right side.
8VLQJWKHUHPRWHFRQWUROWXUQPDLQÀDPHWR21,IWKH
pilot does not light within 60 seconds, stop and go to Step
5.
9.
Refer to remote control instructions for detailed information,
control features, and operation. Note: There is a switch on
the side of the Electronic Control Module that allows for
a continuous standing pilot mode or an intermittent pilot
mode. See appliance manual for location of this switch.
If the pilot or burner does not stay lit (in the standing
SLORWPRGHVWRSDQGLPPHGLDWHO\FDOODTXDOL¿HGVHUYLFH
technician or gas supplier.
10. If the burner or pilot does not operate properly after
several tries, turn the gas control knob clockwise
to "OFF" and call your service technician or
gas supplier.
11. Close bottom louver assembly.
12. Operation of the gas valve, blower, and/or optional light
must be controlled by using the hand held remote control.
Refer to remote instructions for detailed operation
information.
Содержание DVP42FP30N-4
Страница 20: ...31455 10 1115 Page 20 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN...
Страница 41: ...31455 10 1115 Page 41 3ODFH RJ RQWR WZR SLQV RQ UHDU ORJ VXSSRUW DV VKRZQ EHORZ...
Страница 42: ...31455 10 1115 Page 42 3ODFH RJ RQWR WZR OHIW IURQW SLQV RQ EXUQHU SDQ DV VKRZQ EHORZ...
Страница 43: ...31455 10 1115 Page 43 3ODFH RJ RQWR WZR ULJKW IURQW SLQV RQ EXUQHU SDQ DV VKRZQ EHORZ...
Страница 44: ...31455 10 1115 Page 44 3ODFH RJ RQWR RQH SLQ RQ RJ DQG RQH RQ RJ DV VKRZQ EHORZ...
Страница 45: ...31455 10 1115 Page 45 5 Log assembly is completed...
Страница 48: ...31455 10 1115 Page 48 Figure 75 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 60: ...31455 10 1115 Page 60 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 70: ...31455 10 1115 Page 70 PARTS VIEW...