DVVK-5F FLEX VENT INSTRUCTIONS
The
DVVK-5F FLEX VENT KIT
LQFOXGHVWKHIROORZLQJFRPSR
-
nents:
• (1) Horizontal Termination Cap
IRRWVHFWLRQRI)OH[YHQWZLWKVSDFHUV´ÀXH´RXWHU
SLSHZLWKÀXHDGDSWHUFROODU
•
(1) Wall Firestop/Thimble Assembly
+DUGZDUHSDFNWKDWLQFOXGHVEDQGFODPSVDQGVFUHZV
Flex venting can be installed either vertically or horizontally
RIIRIWKH'936HULHV¿UHSODFHV:KHQLQVWDOOLQJDKRUL]RQWDO
vent run from top connections, maintain at least ½” rise for
every 12” of vent run. When venting horizontal off the rear
vent connections, allow a minimum rise of 2”. Refer to the
Figure 53 when mounting termination near vinyl siding.
CAUTION
:
Always stretch and secure venting with wire or
metal strapping to ensure that the horizontal runs do not sag.
If space permits, it is generally easier to attach venting in the
WRSYHQWFRQ¿JXUDWLRQ
Because of sharp edges, always use gloves when handling
WKHÀH[YHQWFRPSRQHQWV
Vent connections should overlap a minimum of 1” for proper
sealing.
Always follow the general venting requirements for vent ter-
minal location, vent lengths, and clearance to combustible
materials.
INSTALLATION
1. Unpack vent components and check that all items are
included.
2. Check to see that the vent spacer springs are located around
WKH ÀXH YHQW DW ´ DQG ´ LQWHUYDOV DORQJ LWV OHQJWK
See
Figure 64.
If not, stretch the spacer springs to about 15” long
DQG ZUDS WKHP DURXQG WKH ÀXH WKHQ LQWHUORFN WKH HQGV RI
each spring about 2”.
See Figure 65.
Maintain equal distance
EHWZHHQVSULQJVSDFHUV
Figure 64
Figure 65
3. Use existing 8” diameter inlet collar to attach outer vent pipe.
4. Install the Wall Firestop/Thimble assembly as required
WKURXJKWKHZDOO5HIHUWRWKHYHQWLQJFKDUWVLQWKHILUHSODFH
manual to determine the proper height and size of the vent
RSHQLQJ 7KH PLQLPXP RSHQLQJ VKRXOG EH ´ ZLGH E\ ´
high. The minimum combustible clearance from the horizontal
vent is 1” from sides and bottom, and 3” above the vent pipe.
See Figure 67.
5. In most cases, after determining the length of the vent that
is needed, it may be easier to install the flue and outer vent
pipes to the Termination Cap first, then from the outside, feed
WKHYHQWLQJWKURXJKWKHZDOOWRWKHILUHSODFH
6. If the venting is to long, trim off any excess vent before
attaching the vent end connectors.
7. Attach the Termination Cap to the outside of the house.
CAUTION: Do not use force when installing the Horizontal
Vent Termination into the flex venting. Always stretch venting
out first, then cut off excessive vent material prior to sliding
the vent termination into the flue and inlet venting. Forcing
the termination cap into the flex venting will deform the flue
venting, which will restrict the exhaust gases, and cause
improper operation of the fireplace.
8. Prior to making the vent connections, apply high temperature
sealant (1000 degree F min.) to the vent connections before
VHFXULQJZLWKWKHEDQGFODPSVSURYLGHG1RWHWKHIOXHSLSH
HQGZLWKRXWWKHDGDSWHULVWREHLQVWDOOHGWRWKH7HUPLQDWLRQ
Cap.
9. Apply sealant to the outside of the flue pipe adapter and
connect to the flex flue pipe. Then insert the adapter into the
ILUHSODFHIOXH6HFXUHIOXHDGDSWHUWRWKHILUHSODFHIOXHZLWKD
PLQLPXPRIWZRVFUHZVSURYLGHG
See Figure 66.
10. Attach the Outer Vent pipe to the 8” diameter collar on the
ILUHSODFHZLWKDODUJHEDQGFODPSSURYLGHG6HDODQWPD\DOVR
be used on the outer vent connections.
11. Check all vent connections for tightness. Make sure horizontal
venting has the proper rise and combustible clearances
required. Refer to venting charts in fireplace instruction
manual.
Figure 66
Figure 67
Содержание DVP42FP30N-4
Страница 20: ...31455 10 1115 Page 20 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN...
Страница 41: ...31455 10 1115 Page 41 3ODFH RJ RQWR WZR SLQV RQ UHDU ORJ VXSSRUW DV VKRZQ EHORZ...
Страница 42: ...31455 10 1115 Page 42 3ODFH RJ RQWR WZR OHIW IURQW SLQV RQ EXUQHU SDQ DV VKRZQ EHORZ...
Страница 43: ...31455 10 1115 Page 43 3ODFH RJ RQWR WZR ULJKW IURQW SLQV RQ EXUQHU SDQ DV VKRZQ EHORZ...
Страница 44: ...31455 10 1115 Page 44 3ODFH RJ RQWR RQH SLQ RQ RJ DQG RQH RQ RJ DV VKRZQ EHORZ...
Страница 45: ...31455 10 1115 Page 45 5 Log assembly is completed...
Страница 48: ...31455 10 1115 Page 48 Figure 75 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 60: ...31455 10 1115 Page 60 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 70: ...31455 10 1115 Page 70 PARTS VIEW...