31455-10-1115
Page 62
MAINTENANCE
Maintenance frequency must be determined individually for each
application. Some considerations are:
([SRVXUHWRZDWHUGLUWFKHPLFDOVDQGKHDWFDQGDPDJHWKH
JDVFRQWURODQGVKXWGRZQWKHFRQWUROV\VWHP
•
Cycling frequency. Appliances that may cycle 20,000 times
annually should be checked monthly.
•
Intermittent use. Appliances that are used seasonally should
EHFKHFNHGEHIRUHVKXWGRZQDQGDJDLQEHIRUHWKHQH[WXVH
'XVW\ZHWRUFRUURVLYHHQYLURQPHQW%HFDXVHWKHVHHQYLURQ
-
ments can cause the gas control to deteriorate more rapidly,
the system should be checked more often.
•
Any control should be replaced if it does not perform properly
on checkout or service. In addition, replace any module if it is
ZHWRUORRNVOLNHLWKDVEHHQZHW
SERVICE
'R QRW GLVDVVHPEOH WKH JDV FRQWURO LW FRQWDLQV QRQUHSODFHDEOH
components. Attempted disassembly or repair can damage the
control.
([DFWO\IROORZWKHZDUQLQJVDQGWKHOLJKWLQJLQVWUXFWLRQV
1. Before lighting, smell around the appliance area for gas. If
the appliance uses LP (bottled) gas, be sure to smell next to
WKHÀRRUEHFDXVH/3JDVLVKHDYLHUWKDQDLU,I\RXVPHOOJDV
immediately shut off the manual valve in the gas piping to the
appliance or on LP at the tank. Do not try to light any appli-
DQFH 'R QRW WRXFK DQ\ HOHFWULFDO VZLWFK RU XVH WKH SKRQH
Leave the building and call your gas supplier. If your gas sup-
SOLHUFDQQRWEHUHDFKHGFDOOWKH¿UHGHSDUWPHQW
7KHJDVFRQWUROPXVWEHUHSODFHGLILWKDVEHHQÀRRGHGZLWK
ZDWHU&DOODTXDOL¿HGVHUYLFHWHFKQLFLDQ
3. The gas control is a safety device. It must be replaced in case
of any physical damage such as bent terminals, missing parts,
stripped threads, or evidence of exposure to excessive heat.
)ROORZWKHRSHUDWLQJLQVWUXFWLRQVSURYLGHGE\WKHPDQXIDFWXUHURI
your heating appliance.
TROUBLESHOOTING
IMPORTANT: All service and trouble-shooting procedures should
EHSHUIRUPHGE\DQH[SHULHQFHGTXDOL¿HGVHUYLFHWHFKQLFLDQ
,IWKHSLORWZLOOQRWVWD\OLW
&RQ¿UP WKDW WKH ³6´ ZLUH DQG WKH ³,´ ZLUH DUH SURSHUO\ FRQ
-
nected to the Control Module “S” and “I” terminals.
&RQ¿UPWKDWWKH6SDUNWR3LORWEXUQHULVSURSHUO\JURXQGHGWR
the Gas Control Valve and the Control Module.
&KHFNWKHSRZHUVRXUFHIURPWKHYROWSRZHUDGDSWRURUWKH
Battery Back-up pack connection and condition of batteries.
&KHFNWKHSRVLWLRQRIWKH&217,182863,/27VZLWFKRQWKH
&RQWURO0RGXOH,IPDLQEXUQHUGRHVQRWFRPH21ZKHQWKH
PDQXDOVZLWFKDQGUHPRWHFRQWUROLVWXUQHG21
D &RQ¿UPWKDWWKHSLORWVSDUNVDQGOLJKWV
E &KHFN WKH WZR SLQ SODVWLF FRQQHFWRUV WKDW SOXJ LQWR WKH
face of the Gas Control valve.
F &RQ¿UPWKDWWKH*DV&RQWUROYDOYHLVSURSHUO\JURXQGHG
to the Control Module.
OPTIONAL GAS CONVERSION KITS
Please contact your dealer or distributor for the proper Conversion
NLW IRU WKHVH ¿UHSODFH PRGHOV &RQYHUVLRQ NLWV ZLOO LQFOXGH FRP
-
SOHWH LQVWUXFWLRQV PLQLPXP UDWH VFUHZ SOXV WKH SLORW DQG PDLQ
EXUQHU RUL¿FH IRU WKH JDV W\SH UHTXLUHG7KH$) (OHFWURQLF
Gas Control Valve is convertible to use either natural or propane
gas by simply turning a small Rotary knob located at the front of
the gas valve. This rotary knob is located under a small rubber cap
DQGVKRXOGRQO\EHDGMXVWHGZKHQFRQYHUWLQJJDVW\SH
CAUTION
:
The gas type has been pre-set at the factory and
PXVWQRWEHFKDQJHGXQOHVVDFRPSOHWHFRQYHUVLRQLVPDGHZKLFK
LQFOXGHV FKDQJLQJ RI WKH JDV SLORW LQMHFWRU PLQLPXP UDWH VFUHZ
DQGPDLQEXUQHURUL¿FH
RF MAINTENANCE INSTRUCTIONS
Содержание DVP42FP30N-4
Страница 20: ...31455 10 1115 Page 20 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN...
Страница 41: ...31455 10 1115 Page 41 3ODFH RJ RQWR WZR SLQV RQ UHDU ORJ VXSSRUW DV VKRZQ EHORZ...
Страница 42: ...31455 10 1115 Page 42 3ODFH RJ RQWR WZR OHIW IURQW SLQV RQ EXUQHU SDQ DV VKRZQ EHORZ...
Страница 43: ...31455 10 1115 Page 43 3ODFH RJ RQWR WZR ULJKW IURQW SLQV RQ EXUQHU SDQ DV VKRZQ EHORZ...
Страница 44: ...31455 10 1115 Page 44 3ODFH RJ RQWR RQH SLQ RQ RJ DQG RQH RQ RJ DV VKRZQ EHORZ...
Страница 45: ...31455 10 1115 Page 45 5 Log assembly is completed...
Страница 48: ...31455 10 1115 Page 48 Figure 75 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 60: ...31455 10 1115 Page 60 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 70: ...31455 10 1115 Page 70 PARTS VIEW...