39358-3-1019
Page 8
Special venting components (Duravent)
See Empire Comfort Systems Retail Price List for Duravent
part numbers and pricing.
Special DV Vent Kits
Available from empire Comfort Systems, Inc. Dealers"
DVVK-4VP
(DVVK-4V)
Direct-Vent Fireplace Vent Kit - Vertical,
Includes 46DVA-VCH, 46DVA-F6 and 46DVA-
SC
DVVK-4tP
(DVVK-4T)
Direct-Vent Fireplace Vent Kit for Top Vent,
Thru-the-wall, 8 to 11 inch wall thickness,
Includes 46DVA-HC, 46DVA-E90, 46DVA-09,
46DVA-08A and 46DVA-WT
DVVK-4RP
(DVVK-4R)
Direct-Vent Fireplace Vent Kit for Rear Vent, 5
to 7 inch wall thickness, (standard thru-the-wall
venting) includes 46DVA-06, 46DVA-HC and
46DVA-WT
DVVK-4RE
Direct-Vent Fireplace Vent Kit For Rear
Vent, Thru-the-wall for 5 to 13 3/4 inch wall
thickness.
DVVK-4tSP
(DVVK-RTS)
Direct-Vent Fireplace Vent Kit for Top Vent,
Thru-the-wall, 5 to 7 inch wall thickness,
Includes 46DVA-HC, 46DVA-E90, 46DVA-06
and 46DVA-WT
*DVVK-4FV Vertical Flex Vent Kit 4" x 7"
*DVVK-4F
Vertical Flex Vent Kit 4" x 7"
VIB6A
Vertical Inlet Baffle Kit For 6 5/8" diameter.
VIB7A
Vertical Inlet Baffle Kit For 7" diameter.
*Empire Flex Vent Kits
VeNt SYSteM IDeNtIFICAtIoN
Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top or out the rear.
NotICE:
Some fireplaces cannot be vented out the rear of the
fireplace.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
When selecting a vent system for use with the fireplace, refer to
the “Special Vent Systems” section in this manual to determine
what systems are acceptable. Check all clearances and venting
components. Identify if any problems existing in the vent system.
Use
Figure 22
on page 17 for top venting, or
Figure 32
on page
21 for rear venting to eliminate issues after installation. Check pipe
diameter on vent system and fireplace to verify the size is the same.
NotICE
: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
Figure 1
*Note:
If using three 90° elbows during horizontal termination.
See Figure 30.
SPeCIAL VeNt SYSteMS
•
Duravent® Pro 4" - 6 ⅝"
•
American Metal Products 4" - 6 ⅝"
•
Selkirk Direct-Temp® 4" - 6 ⅝"
•
Security Secure Vent® 4" - 6 ⅝"
•
Excel DV Venting 4" - 6 ⅝"
•
MetalFab SureSeal® 4" - 6⅝"
•
BDM Manufacturing
•
Olympia VENTIS®
•
Empire Horizontal Round Termination
Kits - DVVK-4RE, DVVK-4FRE,
DVVK-4FREVS,DVVK-4REVS
•
Empire Flexvent Kit DVVK-4F
•
Empire Flexvent Kit DVVK-4FV Vertical
Flex Vent Kit
The following vent systems are acceptable for use with the DVP36 series fireplaces:
Содержание DVP36FP30N-5
Страница 20: ...39358 3 1019 Page 20 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN...
Страница 37: ...39358 3 1019 Page 37 Figure 57 DVVK 4FV DIRECT VENT TERMINATION KIT CONT D...
Страница 46: ...39358 3 1019 Page 46 Figure 70 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...