39358-3-1019
Page 28
HoRIZoNtAL teRMINAtIoN
NotICE:
Termination cap should pass through the wall firestop
from the exterior of the building. Adjust the termination cap to its
final exterior position on the building.
WARNING
termination cap must be positioned so that arrow is pointing up.
Attach the termination cap with the four wood screws provided.
Before attachment of the termination, run a bead of silicone sealant
rated above 250°F on its outside edge too, so as to make a seal
to the exterior wall.
Note:
Wood screws can and should be replaced with appropriate
fasteners for use on stucco, brick, concrete or other types of siding.
CAUtIoN
If exterior walls are finished with vinyl siding (or materials
that could become discolored or warp), it is necessary to
install a vinyl siding standoff.
The vinyl siding standoff will be installed between the vent termination
and the exterior wall.
See Figure 44.
This horizontal vent termination
bolts onto the flat portion of the vinyl siding standoff, so an air space
will exist between the wall and the termination cap.
Figure 44
For installations requiring a vertical rise on the exterior of the
building, 14-inch and 36-inch tall Snorkel Terminations, as shown in
Figure 45
are available. Follow the same installation procedures as
used for standard Horizontal Terminations. If the Snorkel Termination
must be installed below grade (i.e. basement applications, proper
drainage must be provided to prevent water from entering the
Snorkel Termination.
See Figure 46.
Do not attempt to enclose the
Snorkel within the wall or any other type of enclosure.
Natural Models only
Figure 45
Natural Models only
Figure 46
Содержание DVP36FP30N-5
Страница 20: ...39358 3 1019 Page 20 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN...
Страница 37: ...39358 3 1019 Page 37 Figure 57 DVVK 4FV DIRECT VENT TERMINATION KIT CONT D...
Страница 46: ...39358 3 1019 Page 46 Figure 70 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 70: ...39358 3 1019 Page 70 PARTS VIEW...
Страница 78: ...39358 3 1019 Page 78 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...