FULL OPEN AND
FOUR INDICATED
HOLES ALIGNED
2/3 OPEN AND
TWO INDICATED
HOLES ALIGNED
WARNING
Use flue restrictor for vertically terminated units only. Do not
use for horizontally terminated units.
Figures 39 to 41
show the location and recommended openings
for the flue restrictor. Adjustments may be made for each
particular installation.
Figure 39
Note:
When installing flue restrictor, install with screws pointing
in downward position.
LP Setting - Figure 40
Natural Gas Setting - Figure 41
VENTING FIREPLACE - TOP (continued)
Below Grade Installation
When it is not possible to meet the required vent termination
clearances of 12-in (305 mm) above grade level, a snorkel kit is
recommended. It allows installation depth down to 7-in (178 mm)
below grade level. The 7-in (178 mm) is measured from the center
of the horizontal vent pipe as it penetrates through the wall.
Ensure the sidewall venting clearances are observed. If venting
system is installed below ground, we recommend a window
well with adequate and proper drainage to be installed around
the termination area.
6” (152mm)
MINIMUM
PIPE STRAP
48”
(1219mm)
COMBUSTIBLE
PROJECTION
18” (457mm)
MINIMUM
12” (305mm)
ABOVE GRADE
OR EXPECTED SNOW
TYPICAL BASEMENT INSTALLATION
TYPICAL BASEMENT INSTALLATION
Figure 42