29004-0-0711
Page 9
Figure
1
FIREpLACE DIMENSIONS
DIMENSION
DLCX36Sp
A
34 3/4”
B
39"
C
18”
D
21"
E
36”
F
N/A
G
N/A
H
41 1/8”
I
1 1/4”
J
5 3/8"
K
2 1/2”
L
6”
M
25"
N
33 1/2”
MAX WEIGHT (LB)
167
C
K
K
L
L
B
E
32 1/2
I
J
D
M
N
A
H
11 1/2
9
When planning a fireplace installation, it is necessary to determine
the following:
•
The vent system configuration to be used.
•
Gas supply piping.
•
Electrical supply requirements for blower and valve system.
•
Properly framed opening size required for installation of the
fireplace.