Page 42
36776-4-0117
TROUBLESHOOTING (CONT'D)
PROBLEM OBSERVED
POSSIBLE CAUSE
CORRECTIVE MEASURE
Gas odor during setup
Gas Leak
What To Do If You Smell Gas
Do not try to light any appliance.
Do not touch any electrical switch;
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Gas odor before first ignition
Gas Leak
Fireplace is on but no flame and pilot
is not trying to light
Gas Line Valve turned off
Turn shutoff valve to open position
Control module in lockout
Turn power to fireplace off and then back on
Pilot continues to spark when pilot is
lit.
Not enough gas to pilot
Wait for pilot flame to strengthen
Low Gas Pressure
Check pressures. See page 40.
Pilot igniter/sensor is dirty
Clean pilot. See maintenance page 39.
Pilot not grounded well
Check ground connections
Draft in firebox
Redirect draft from room or wall
Pilot sensor has been bent
Replace pilot
Pilot will not ignite, or will not stay lit
Pilot igniter/sensor is dirty
Clean flame sensor and pilot igniter. See
maintenance page 39.
Pilot not grounded well
Check ground connections
Sensor Wire loose
Check sensor wire terminals
Gas pressure incorrect
Adjust gas pressure
Pilot Gas Line bent or kinked
Replace pilot tube
Faulty pilot, Sensor bent
Replace Pilot
Faulty valve
Replace Valve
Burner takes too long to fully light
Low gas pressure
Check gas supply pressure
Clogged or dirty carryover/burner ports
Clean ports
Blocked orifice
Check orifice opening
Faulty valve
Replace valve
Burner does not light but pilot remains
on
Low gas pressure
Check gas supply pressure
Clogged or dirty burner ports
Clean burner ports
Blocked orifice
Check orifice opening
Loose wire connections
Check valve/control module connections
Faulty pilot
Replace pilot
Faulty valve
Replace valve
Burner lights but does not stay lit while
pilot remains on
Low gas pressure
Check gas supply pressure
Loose sensor wire
Check wire connection
Faulty valve
Replace valve
Faulty pilot or thermocouple
Replace Safety pilot
Clogged or dirty burner ports
Clean burner ports
Room temperature is higher than
thermostat setting
Move remote away from fireplace
Set higher temperature on remote/thermostat
Remote control batteries failing
Replace batteries in remote transmitter and
receiver