Page 38
36776-4-0117
OPERATING INSTRUCTIONS
5.25 VDC ELECTRONIC CONTROL VALVE
The electronic control valve system includes the ability to switch
the pilot from a standing pilot mode to an intermittent pilot mode.
•
IP Mode
- In the Intermittent Pilot mode, when the
fireplace is turned ON, it will cause spark to the pilot,
light the pilot, then allow the burner to light. When the
fireplace is turned to OFF, both the burner and pilot will
be OFF.
•
CPI Mode
- In the Continuous Pilot mode, the pilot
remains ON continuously even when the burner is
turned OFF.
Notice:
A small toggle switch is located on control module
shield that is used to switch from IP (upward position) to the CPI
(downward position). (See Figure 64)
REMOTE
CONTROL
RECEIVER
PILOT SELECTOR SWITCH
•
IPI - INTERMITANT PILOT (UP)
•
CPI - CONTINUOUS PILOT (DOWN)
SPARK ROD
GROUND
9 PIN
CONNECTOR
PILOT
SENSOR
STEPPER
MOTOR
REGULATOR
GAS VALVE
OUTLET
PRESSURE
TAP
INLET
PRESSURE
TAP
SENSOR
DFC
ELECTRONIC
CONTROL
MODULE
IPI
CPI
PILOT
ASSEMBLY
IGNITOR
Figure 64
When the fireplace is turned to ON, the electrical current will
energize a spark to the pilot igniter. Once the pilot sensor heats
up (after a few seconds), the valve will be energized, allowing
gas to flow to the burner.
1. Follow the SAFETY and LIGHTING INSTRUCTIONS for
Intermittent Pilot controls found in this manual, and on labels
found in the control compartment located in the lower cavity
of the fireplace.
2. The gas valve has inlet and outlet pressure taps as shown in
Figure 67. (Refer to page 40 for gas pressure requirements)