11. Place batteries in receiver boxes and remotes using
instructions provided. Verify remote is communicating with
receiver.
Important! If installing a decorative front, an offset between the
finishing materials and fireplace opening is required. Refer to
the installation instructions provided with the decorative front for
more information.
For installation of the DFL601BL-1, DFL602BL, DFL721BL,
and DFL722BL
kits, 1/2-inch unfinished space is required to
either side of the fireplace installation.
1/2”
1/2”
For installation of the DFL602NB & DFL722NB kits, 7/8-inch
unfinished space is required on all four sides of the fireplace
opening.
7/8”
7/8”
7/8”
7/8”
3 3/8”
FINISHED
WALL
APPLIANCE
OPENING
NON-COMBUSTIBLE
BOARD INSTALLED
ON BOTH SIDES
NON-COMBUSTIBLE
BOARD INSTALLED
OVER APPLIANCE OPENING
Figure32
Note: Standoffs and Non-Combustible Board shown for reference
FIREPLACE
OPENING
NON-COMBUSTIBLE
BOARD INSTALLED
OVER FIREPLACE FACE
NON-COMBUSTIBLE
BOARD INSTALLED
ON BOTH SIDES
12-1/4”
FINISHED
WALL
PAINTED
FINISHED
PAINTED WALL
STANDOFFS
FRAMING
FRAMING
HEADER
18-15/16”
Figure 33
NOTE: Nailing Flanges and Non-Combustible Board shown
for reference.
12. Install Non-Combustible Board (See Figure 32)
•
Non-combustible board has been provided with the fireplace.
•
Do not attach non-combustible board to the fireplace. Attach
non-combustible board only to side studs, standoffs and
header board.
•
Space non-combustible board 1/16 inch off of fireplace
opening flanges to allow for expansion during operation.
•
Predrill holes into non-combustible board and counter-sink.
•
For best results treat non-combustible board and area
around the board with Kilz prior to applying adhesive or
sealing compound.
•
Apply adhesive in joints between non-combustible board
panels.
•
Use only high-temperature adhesive and high-temperature
paints rated for minimum 300
o
F with the non-combustible
board.
13. Finish Wall.
•
Use woven fiberglass joint tape and Durabond 45 joint
compound for best results when finishing non-combustible
panel and drywall joints around fireplace.
•
Tile or noncombustible materials can be applied on top of the
non-combustible board and finished wall as their instructions
require.
FIREPLACE & NONCOMBUSTIBLE BOARD
INSTALLATION - CLEAN FACE