43
38
39 EMERGENCY STOP
SOURCE 2
SOURCE 2
40 SOURCE 1 FAIL TO START ALARM
41 SOURCE 1 FAIL TO STOP ALARM
44
45 SOURCE 2 AT REST
46 SOURCE 2 AVAILABLE
47 SOURCE 2 CLOSED AUXILIARY
48 SOURCE 2 FAILED TO CLOSE
49 SOURCE 2 FAILED TO OPEN
50 SOURCE 2 HIGH FREQUENCY
51 SOURCE 2 FAILURE
52 SOURCE 2 HIGH VOLTAGE
53 RESERVED
54 SOURCE 2 LOAD INHIBIT
55 SOURCE 2 LOW FREQUENCY
56 RESERVED
57 SOURCE 2 LOW VOLTAGE
This output indicates that an emergency stop alarm has occurred.
This output indicates that the engine 1 has not started after the specified number of attempts.
This output indicates that the generator 1 has failed to stop within the selected time
The output indicates that the generator 2 is not running.
This output indicates when the generator 2 is ready to accept load, i.e. warm up timer has timed out.
This output indicates that a digital input that has been configured as 'Source 2 closed auxiliary' is active.
This output source has intended to be used to indicate a failure of the Source 2 contactor or breaker. It can only
be used if the unit is configured to use 'Source 2 closed auxiliary' feedback.
This output source has intended to be used to indicate a failure of the source 2 contactor or breaker. It can only
be used if the unit is configured to use 'Source 2 closed auxiliary' feedback.
This output indicates that the unit has sensed that the incoming Source 2 frequency has exceeded the frequency
limit setting.
This output indicates that the unit has sensed that a failure of the Source 2. This output will become active
whenever the Source 2 voltage or frequency goes out of limits, or if the auxiliary Source 2 failure input active (if
used) and the Source 2 fail timer has expired.
This output indicates that the unit has sensed that the incoming Source 2 voltage has exceeded the voltage limit
setting.
This output indicates that a digital input has been configured as ‘Source 2 load inhibit' is active.
This output indicates that the unit has sensed that the incoming Source 2 frequency has fallen below the
frequency setting.
This output indicates that the unit has sensed that the incoming Source 2 voltage has fallen below the voltage
limit setting.
40
FAIL TO START ALARM
41
FAIL TO STOP ALARM
This output indicates that the engine 2 has not started after the specified number of attempts.
This output indicates that the generator 2 has failed to stop within the selected time
DIGITAL INPUT8 ALARM
This output indicates that digital input 8 alarm has occurred.
RESERVED