background image

24

Output Functions

Output Run Type

Output Pulse Time

Counting Direction

S1

S

V

O1

O

P

RESET

P

SET

S1

S

V

O1

O

P

RESET

P

SET

S1

S

V

O1

O

P

RESET

P

SET

S1

S

V

O1

O

P

RESET

P

SET

You can change the 
p a r a m e t e r   w i t h  
INCREMENT button, 
save it to the memory and 
p a s s   t o   t h e   n e x t  
parameter with ENTER 
button.

Press Enter Button

The most significant digit of 
the parameter (1st digit for 
this parameter) flashes.

Press PROG button to exit 
from programming section 
without doing any 
changes.

You can change the 
p a r a m e t e r   w i t h  
INCREMENT button, 
save it to the memory and 
p a s s   t o   t h e   n e x t  
parameter with ENTER 
button.

Press Enter Button

Press PROG button to exit 
from programming section 
without doing any 
changes.

You can change the 
p a r a m e t e r   w i t h  
INCREMENT button, 
save it to the memory and 
p a s s   t o   t h e   n e x t  
parameter with ENTER 
button.

Press Enter Button

Press PROG button to exit 
from programming section 
without doing any 
changes.

You can change the 
p a r a m e t e r   w i t h  
INCREMENT button, 
save it to the memory and 
p a s s   t o   t h e   n e x t  
parameter with ENTER 
button.

Press Enter Button

The most significant digit of 
the parameter (1st digit for 
this parameter) flashes.

Press PROG button to exit 
from programming section 
without doing any 
changes.

The most significant digit of 
the parameter (1st digit for 
this parameter) flashes.

The most significant digit of 
the parameter (4th digit for 
this parameter) flashes.

Содержание EZM-9935

Страница 1: ...r 6 digits Process PV and 6 digits Set SV Value Display Operation with 1 Set Value Reset Pause and Start Inputs Operation with Automatic and Manual Reset NPN PNP Type Operation EZM 9935 96 x 96 DIN 1...

Страница 2: ...ce to the system are explained Operation and Parameters In this section user interface of the device how to access to the parameters description of parameters are explained Also in these sections ther...

Страница 3: ...3 5 INPUT CONNECTION 3 5 1 PROXIMITY CONNECTION 3 5 2 SWITCH CONNECTION 3 6 RELAY OUTPUT WIRING DIAGRAM 3 7 GALVANIC ISOLATION TEST VALUES OF EZM 9935 PROGRAMMABLE TIMER 4 DEFINITION OF FRONT PANEL A...

Страница 4: ...o the following directives 2006 95 EC The Low Voltage Directive 2004 108 EC The Electromagnetic Compatibility Directive has been designed and manufactured to the following specifications EN 61000 6 4...

Страница 5: ...control rollers and can be adapted easily to all mechanical construction and automation system Some application fields which they are used are below Standart EZM 9935 Standart Supply Voltage Input 230...

Страница 6: ...livered is free from defects in material and workmanship This warranty is provided for a period of two years The warranty period starts from the delivery date This warranty is in force if duty and res...

Страница 7: ...the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented Never attempt to disassemble modify or repair this unit Tampering with the unit may...

Страница 8: ...tion NEMA 4X Panel surface maximum thickness 15 mm 0 59 inch 96 mm 3 78 inch Maximum 15 mm 0 59 inch 96 mm 3 78 inch 84mm 3 31 inch 11 5 1 mm 0 45 inch Mounting Clamp EZM 9935 Timer RESET P S1 SV O1 O...

Страница 9: ...10 2 3 Panel Cut out 9 129 mm 5 08 inch min 92 mm 3 62 inch 92 mm 3 62 inch 129 mm 5 08 inch min...

Страница 10: ...Before mounting the device in your panel make sure that the cut out is the right size 2 Check front panel gasket position 3 Insert the device through the cut out If the mounting clamps are on the unit...

Страница 11: ...will not fall while doing the montage The unit is designed for panel mounting 1 Insert the unit in the panel cut out from the front side 2 Insert the mounting clamps to the holes that located top and...

Страница 12: ...tion is correct Parameters of the device has factory default values These parameters must be set according to the system s needs Only qualified personnel and technicians should work on this equipment...

Страница 13: ...V 15 10 50 60Hz 2 3VA Relay Output 14 a a P N EZM 9935 Y c 11 1213 15 1 2 3 4 5 NO C NC 5A 250VV c 3 2 Electrical Wiring Diagram Electrical wiring of the device must be the same as Electrical Wiring D...

Страница 14: ...3 3 View of Device Label 14 1 Y ca L N 50 60 Hz 2 3VA 230 VV 15 P N EZM 9935 11 12 13 14 15 NC NO C 5A 250VV 12 V Z Max 50mA 2 0 V Z Start 5 Pause 4 3 Reset...

Страница 15: ...ge must be applied to the unit Controlling prevents damages in unit and system and possible accidents as a result of incorrect supply voltage There is no power supply switch on the device So a power s...

Страница 16: ...2 V Z Max 50mA 0 V Z PAUSE PROX PROX RESET PNP PNP PROX PNP START NOTE 1 1 3 2 4 5 12 V Z Max 50mA 0 V Z PAUSE PROX PROX RESET NPN NPN PROX NPN START PNP type operation NPN type operation NOTE 1 Senso...

Страница 17: ...itch Switch 1 3 2 4 5 PAUSE RESET NOTE 1 Switch Switch NOTE 1 0 V Z 12 V Z Max 50mA 0 V Z 12 V Z Max 50mA Switch START Switch START PNP type operation NPN type operation NOTE 1 Sensor supply voltage 1...

Страница 18: ...ammable Counter Supply Voltage 500V V for EZM 9935 3 2000V V for EZM 9935 5 12V Z Sensor Supply Voltage Relay Outout 3 6 Relay Output Wiring Diagram Fuse Load Last Control Element Contactor 5A V T Fus...

Страница 19: ...NT Button is used to Reset the Actual Value or increment the digit value that is selected by SHIFTING Button ENTER Button is used for saving all changes to memory and accessing to the parameters SHIFT...

Страница 20: ...EZM 9935 Programmable Timer and Software Revision on the Display When power on view of the screen is shown below When power is applied to the device software revision number of the controller is on ac...

Страница 21: ...OP S1 SV O1 OP RESET P SET RESET P SET RESET P SET RESET P SET RESET P SET RESET P SET When shift button is pressed 6th digit of SET value starts to flash Press Shift button again 5th digit of SET val...

Страница 22: ...named MANUAL RESET in parameters section At the end of MANUAL RESET if then Count value becomes 0 value If then Count value becomes SET value S1 SV O1 OP S1 SV O1 OP RESET P SET RESET P SET 4 4 Resett...

Страница 23: ...The most significant digit of the parameter 1st digit for this parameter flashes The most significant digit of the parameter 4th digit for this parameter flashes Press Enter Button Filter time for Re...

Страница 24: ...button Press Enter Button Press PROG button to exit from programming section without doing any changes You can change the p a r a m e t e r w i t h INCREMENT button save it to the memory and p a s s...

Страница 25: ...TER button Press Enter Button The most significant digit of the parameter 1st digit for this parameter flashes Press PROG button to exit from programming section without doing any changes You can chan...

Страница 26: ...26 S1 SV O1 OP RESET P SET S1 SV O1 OP RESET P SET Continue to press ENTER button for scanning all parameters Time Unit and Scale Selection Operation Screen...

Страница 27: ...me It can be adjusted from to msec 8 PARAMETRELER 5 Program Parameters Time Unit and Scale Selection Hour Minute It can be adjusted from to Minute Second It can be adjusted from to Second Milisecond I...

Страница 28: ...es while Start input is active When Start input is passive count value becomes 0 When Manual Reset happens count value becomes 0 value Counting direction P 0 Downcounting When count value reaches the...

Страница 29: ...ens count value becomes 0 value Counting is continues while Start input is active When Start input is passive count value becomes 0 Counting direction P 0 Downcounting When count value reaches the 0 O...

Страница 30: ...the SET value When Manual Reset happens count value becomes 0 value When Start input is passive count value becomes 0 Counting direction P 0 Downcounting When count value reaches the 0 Value Output P...

Страница 31: ...mes 0 value When count value reaches the 0 Value Output Position is changed Actual value is reset automatically If Start input is active then counting starts downcounting at Set value If Output Pulse...

Страница 32: ...nput is active then counting starts from 0 value If output pulse time is 0 then output position has not change until Manual Reset happens Actual counting value stops at SET value Counting process is n...

Страница 33: ...ive then counting starts from Set value If output pulse time is 0 then output position has not change until Manual Reset happens Actual counting value stops at 0 value Counting process is not continue...

Страница 34: ...alue reach SET value output position becomes active position and if the Start input is active then count value starts counting from 0 value But SET value is observed in actual value display Counting p...

Страница 35: ...until Manual Reset happens When counting value reach 0 value output position becomes active position and if the Start input is active then count value starts counting from Set value But 0 value is ob...

Страница 36: ...has not change until Manual Reset happens When counting value reach Set value output position becomes active position If the Start input is active then counting continue over the Set value When Manua...

Страница 37: ...sition If output pulse time then output position has not change until Manual Reset happens When counting value reach 0 value output position becomes active position If the Start input is active then c...

Страница 38: ...position When manual reset happens count value becomes SET value If the Start input is active then Process starts counting until count value reach SET value When count value reach SET value Output Pos...

Страница 39: ...unt value is saved to memory when power is disconnected and restored on power up Count value is not saved to memory when power is disconnected When power up is shown on the screen Sensor Type Selectio...

Страница 40: ...play If program password is not 0 while accessing to the program parameters 1 If user does not enter the value correctly operation screen will appear without entering to operator parameters 2 When in...

Страница 41: ...meter but user can not do any changes in parameters If password is entered for accessing to the parameters correctly most significant digit of the parameter flashes But if the password is not entered...

Страница 42: ...of the count value is lower than the minimum count value To remove this warning and reset the count value press RESETbutton 2 If Actual Value is flashing and counting is stopped It appears if any of t...

Страница 43: ...rical Characteristics Rated voltage 16 VZ 5mA Maximum continuous permissible voltage 30 VZ Logic 1 minimum level 3 VZ Logic 0 maximum level 2 VZ Sensor Supply Voltage Electrical Characteristics 12VZ 4...