TIMER

● Operating voltage to wide range(AC 85~265V 50/60Hz)

● Can set 20 groups on-off program, set weekly cycle and day cycle and manually control on-off

● Have a function of countdown, and the range of time 1 second ~ 99minutes and 59 seconds

● Can manually set Daylight Saving Time(+/- 1 hour)

● Built-in lithium battery, and travel time as usual after power failure

● Can check accumulated operational time and action times

● Can auto-correct time(-3 sec ≤

t≤3 sec) every day

Technical data

Rated voltage

85~265VAC 50/60Hz

Power failure memory:

3 year

Times of switch setting:

20 groups on/off program

Stand-by consumed power

≤ 1.5VA

Contact Form:

1 group conversion

Relay pull power

≤ 3VA

Contact load capacity: resistance load

Resistance load
16A/ 250V AC

COSφ=1

Electrical life

10

5

times

Mechanical life

10

7

times

Countdown time

1 sec- 99min59sec

Work temperature

-10 ~ +50

O

C

(non-icing

Contact resistance between contacts:

≤100mΩ

Ambient humidity

35

85

RH

Insulation resistance between contacts

≥100MΩ

Storage temperature

-10 ~ +60

O

C

Timing error

≤±2sec/day(25

)

Weight

About 150g

Wiring drawing and external dimension

Setting method

* If no any action procedure within 30 seconds, all set operations will exit automatically, and that will not be saved

* If no display for the first time, please press “RESET”.(in addition, press “D+” and “H+” for 3 seconds, then the product will be
closed, all setting will be lost but day correction parameter, accumulated operational time and action times will not be reset.)

Setting display time(present time)

Step

Key

Programming

1

press

and

H+

hour increases on the screen, continuously press H+, then hours increase

2

press

and

M+

minute increases on the screen, continuously press M+, then minutes increase

3

press

and

D+

mark of week moves on the screen, continuously press D+ to choose week

* When it starts, the timer is in 24-hour system, please press “

” for 5 seconds, the ”AM” will display at bottom-left corner of

LCD, it represent 12-hour system, press”

” for 5 seconds again, go back 24-hour system and “AM” mark disappeared.(

When

the 12-hour system AM in the morning, PM in the afternoon

.)

20 groups setting of procedure switch

1. Setting program group ON/OFF time, can’t setting overlap, should be according the time sequence.(If setting same ON/OFF

time, after contact 15 seconds, will have ring a bell function ect)

2. Setting program group ON/OFF time, first step, setting present time , second step, setting the ON/OFF program, after