28
=
=
Or
=
=
Or
Manual Reset-1.
Device continues to count till manual reset is applied.
(Output PulseTime is not considered)
Output Functions
Count direction : 0 --> P (Upcounting)
=
When count value reaches the Set Value, Output Position is changed.
Counting process continues over the SET value
.
Output Pulse Time is
not considered. Process counts, until manual reset happens. Counting
is continues, while Start input is active. When Start input is passive,
count value becomes “0”. When Manual Reset happens, count value
becomes 0 value.
Counting direction : P --> 0 (Downcounting)
=
When count value reaches the 0 Value, Output Position is changed.
Counting process continues under the 0 value
.
Output Pulse Time is not
considered. Process counts, until manual reset happens. Counting is
continues, while Start input is active. When Start input is passive, count
value becomes SET value. When Manual Reset happens, count value
becomes SET value.
0
Set
Reset
Output
Start
0
Set
Reset
Output
Start