38
Or
Or
=
=
=
=
Automatic Reset-5
is not considered.
If the Start input is active, then Process starts counting,
until
count value
reach “0” value. When count value reach “0” value, Output Position
becomes active position and process is automatically reset. If the Start
input is active, then process start counting from SET value. If count
value reach “0” value, Output Position becomes passive position.
When manual reset happens, count value becomes SET value.
If the Start input is active, then Process starts counting,
until
count value
reach SET value. When count value reach SET value, Output Position
becomes active position and process is automatically reset. If the Start
input is active, then process start counting from “0” value. If count value
reach SET value, Output Position becomes passive position.
When manual reset happens, count value becomes “0”.
Counting direction : 0 --> P (Upcounting)
=
Counting direction : P --> 0 (Downcounting)
=
0
Set
Reset
Output
Start
0
Set
Reset
Output
Start