E-mail: [email protected]
Made in Rome, New York, USA
8
SCC/SHC DIMENSIONS & SPECIFICATIONS
NOTE:
All EMI products are subject to ongoing development programs so design and specifications may change without notice.
MOUNTING DIMENSIONS
09-15
18-36
20
5
/
8
”
SCC/SHC Electrical Specifications
Model#
Volts/HZ/PH
Fan Motor
Compressor
Total
AMPS
Min
Volt
M.C.A. HACR
BRKR
AMPS
HP
RLA
LRA
115V 60Hz
09AA
115/60/1
1.6
0.125
7.4
44
9
104
10.9
15
12AA
1.6
0.125
9.7
54
11.3
104
13.7
20
208/230V 60Hz
09DM
208/230/60/1
1
0.125
4.1
20
5.1
197
6.1
15
12DM
1
0.125
5.1
28
6.1
197
7.4
15
15DM
1
0.125
6.4
35
7.4
197
9.0
15
18DF
1
0.125
7.4
48
8.4
197
10.3
15
24DF
1
0.125
9.6
60
10.6
197
13.0
20
30DF
1
0.125
11.8
73
12.8
197
15.8
25
36DF
1.8
0.333
14.4
86
16.2
197
19.8
30
265/277V 60Hz
09EM
265/277/60/1
1
0.125
3.3
18
4.3
240
5.1
15
12EM
1
0.125
4.2
28
5.2
240
6.3
15
15EA
1
0.125
5.4
32
6.4
240
7.8
15
18EF
1
0.125
6.5
44
7.5
240
9.1
15
24EF
1
0.125
8.2
58
9.2
240
11.3
15
30EF
1
0.125
10.4
72
11.4
240
14.0
20
36EF
1.8
0.333
13
90
14.8
240
18.1
30
220/240 50 Hz
09FA
220/240/50/1
1
0.125
3
18.6
4
198
4.8
15
12FA
1
0.125
4.1
28
5.1
198
6.1
15
15FA
1
0.125
5.2
32
6.2
198
7.5
15
18FF
1
0.125
6.7
42
7.7
198
9.4
15
24FF
1
0.125
8.4
55
9.4
198
11.5
15
30FF
1
0.125
10.7
70
11.7
198
14.4
25
36FF
1.8
0.333
13.4
85
15.2
198
18.6
30
SCC/SHC PHYSICAL DIMENSIONS AND PIPING SPECIFICATIONS
UNIT
SIZE
WIDTH
HEIGHT
DEPTH
SHIPPING
WT. (LBS.)
INTERCONNECTING
REFRIGERANT LINE
SIZES
09, 12
34 1/8”
22 1/4”
12”
90
1/4”
1/2”
15
34 1/8”
22 1/4”
12”
90
1/4”
5/8”
18
44”
26 1/4”
14”
135
3/8”
5/8”
24, 30
44”
26 1/4”
14”
155
3/8”
3/4”
36
44”
26 1/4”
14”
155
3/8”
7/8”
SCC/SHC PERFORMANCE DATA*
MODEL
COOLING
HEATING
BTUH
SEER
BTUH
HSPF
09
9,500
10.5
9,000
7.1
12
12,000
10.0
11,200
7.0
15
15,800
10.3
14,100
7.1
18
18,600
10.3
18,000
7.0
24
24,000
10.6
21,500
7.3
30
28,400
10.2
26,200
7.9
36
33,000
10.0
31,000
6.8
* When paired with EMI’s highest sales volume
combinations