background image

www.enviromaster.com

High Efficiency Condensing Units

15

ALL PRODUCT LIMITED WARRANTY

Enviromaster International LLC (EMI) warrants to the purchaser/owner that EMI products will be free from 

defects in material and workmanship under the normal use and maintenance for a period of twelve months for 

all components and sixty months on unit compressors from the date of original installation, or fifteen months 

for all components and sixty-three months on unit compressors from the date of manufacture, whichever 

comes first.

WHAT WE WILL COVER

EMI will replace any defective part returned to EMI's approved service organization with a new or rebuilt part 

at no charge. The replacement part assumes that unused portion of this warranty.

WHAT WE DON'T COVER

THIS WARRANTY DOES NOT INCLUDE LABOR

 or other costs incurred for repairing, removing, installing, 

shipping, servicing, or handling of either defective or replacement parts.

EMI IS NOT RESPONSIBLE FOR:

• Normal maintenance

• Damage or repairs required as a consequence of faulty installation or application by others. 

• Failure to start due to voltage conditions, blown fuses, open circuit breakers, or other damages due to the 

inadequacy or interruption of electrical service.

• Damage or repairs needed as a consequence of any misapplication, abuse, improper servicing, unauthor-

ized alteration, or  improper operation.

• Damage as a result of floods, winds, fires, lightening, accidents, corrosive atmosphere, or other conditions 

beyond the control of EMI.

• Parts not supplied or designated by EMI.

• Products installed outside the United States or Canada.

• Any damages to person or property of whatever kind, direct or indirect, special or consequential, Whether 

resulting from  use or loss of  use  of the product.

LIMITATION OF WARRANTIES

This warranty is exclusive and in lieu of any implied warranties of merchantability and fitness for a particular 

purpose and all other warranties express or implied. The remedies provided for in this warranty are exclusive 

and shall constitute the only liabilities on the part of EMI including any statements made by any individual 

which shall be of no effect.

FOR SERVICE OR REPAIR:

(1) Contact the Installer

(2) Call the nearest Distributor

(3) Call or write:

5780 Success Dr., Rome, NY 13440

Phone: 1-800-228-9364

FAX: 1-800-232-9364

Email: [email protected]

Содержание MC2 Series s

Страница 1: ...com INSTALLATION OPERATION AND MAINTENANCE MANUAL EMI AMERICASERIES SINGLE ZONE MULTI ZONE CONDENSING UNITS MC4 MH4 MULTI ZONE MC2 MH2 DUAL ZONE SCC SHC SINGLE ZONE STRAIGHT COOL HEAT PUMPS Nominal Ca...

Страница 2: ...er_________________________ Date of installation______________________ SAFETY INSTRUCTIONS Read all instructions before using the EMIAmericaSeries high ef ciency condensing unit Install or locate this...

Страница 3: ...may cause damage to the compressor and coil and could result in freezing that may void the warranty We accomplish the low ambient operation on our condensers by cycling the condenser fan When in low...

Страница 4: ...alent feet Whether the outdoor unit is above or below the indoor unit a P trap is recommended if the suction riser is 20 feet or higher NOTE Avoid excessive oil buildup The P trap should have a shallo...

Страница 5: ...panels and make sure they are properly secured Make nal visual inspection and repair any de ciencies NOTE A hard start kit may be required for units in low volt age frequent cycle applications OPERATI...

Страница 6: ...ommended for field charging or checking the existing refrigerant charge in a system Because each installation is different in terms of indoor air ow refrigerant line length etc the factory charge may...

Страница 7: ...80 198 5 215 5 235 0 203 5 212 0 226 0 237 0 85 208 5 230 5 252 0 218 0 227 0 242 5 253 0 90 223 0 246 0 270 0 233 5 241 5 259 0 270 0 95 241 5 263 0 285 0 250 5 256 0 275 5 285 0 100 264 0 280 5 300...

Страница 8: ...1 0 125 5 4 32 6 4 240 7 8 15 18EF 1 0 125 6 5 44 7 5 240 9 1 15 24EF 1 0 125 8 2 58 9 2 240 11 3 15 30EF 1 0 125 10 4 72 11 4 240 14 0 20 36EF 1 8 0 333 13 90 14 8 240 18 1 30 220 240 50 Hz 09FA 220...

Страница 9: ...52 OZ 46 5 OZ 49 5 OZ 56 5 OZ 55 OZ 58 OZ 65 OZ 18 CHP 24 FHP 24 WHP 18 TBH 24 CAH 24 56 OZ 10 25 50 6 OZ 14 OZ 28 OZ 35 OZ 41 OZ 41 OZ 49 OZ 63 OZ 47 OZ 55 OZ 69 OZ 24 CHP 24 FHP 24 WHP 30 TBH 24 CA...

Страница 10: ...rankcase heater This will offer protection against cold start situations thus prolonging the life of the compressor NOTE The crankcase heater is installed when the low ambient control option is select...

Страница 11: ...8 20 6 7 48 9 6 60 21 9 24 3 30 197 9508 1 8 0 33 3 8 20 6 7 48 7 4 48 19 7 21 6 25 197 2208 1 0 125 4 8 26 3 4 8 26 3 7 4 48 18 19 9 25 197 2008 1 0 125 4 8 26 3 7 4 48 13 2 15 1 20 197 9999 1 0 125...

Страница 12: ...erant charge protection NOTE The crankcase heater is installed with 9 15K Btu heat pumps and when the low ambient control option is selected MC2 MH2 DUAL ZONE High Ef ciency Condensing Unit Limited Ra...

Страница 13: ...0 0 125 4 8 26 3 4 8 26 3 10 6 11 8 15 9200 208 230 60 1 1 0 0 125 3 8 20 4 8 26 3 9 6 10 8 15 5500 208 230 60 1 1 8 0 25 6 4 38 6 4 38 14 6 16 2 20 1 Circuit Designators 9 9 000 Btuh 2 12 000 Btuh 5...

Страница 14: ...unit SCC SHC pg 8 MC4 MH4 pg 9 MC2 MH2 pg 11 or call the factory Anti short cycle protection should be used on systems that use a con ventional thermostat Evaporator Entering Air WB Evaporator Leaving...

Страница 15: ...others Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service Damage or repairs needed as a consequen...

Страница 16: ...E mail emi enviromaster com Made in Rome New York USA 16...