30
g- 20 ( HEX ) ; 67 ( HEX ) ; 20 ( HEX ) ; 20 ( HEX )
Ib-20 ( HEX ) ; 6C ( HEX ) ; 62 ( HEX ) ; 20 ( HEX )
kg-20 ( HEX ) ; 6B ( HEX ) ; 67 ( HEX ) ; 20 ( HEX )
oz-20 ( HEX ) ; 6F ( HEX ) ; 7A ( HEX ) ; 20 ( HEX )
9.5 Transmit format(P cont: series transmission)
EX+0.876g, when it is stable and gross weight as:
HEAD, HEAD, DATA UNIT CR
ST , GS , + 0.876 g 0D 0A
EX-1.568lb, when it is unstable and net value as:
HEAD, HEAD, DATA UNIT CR
US , NT , - 1.568 lb 0D 0A
EX, when it is overloaded and net value as:
HEAD, HEAD, DATA UNIT CR
OL , NT , - - - - - - - - oz 0D 0A
9.6 Format (OFF)
When the scale receives specific request from peripheral device, the scale will send weight
data to peripheral device.
“ENQ” -> 05H “EOT” -> 04H
“ACK” -> 06H “DC1” -> 11H
“NAK” -> 15H “SOH” -> 01H
“STX” -> 02H “ETX” -> 03H
“DC1” ->11H
SOH STX STA SIGN W6 W5 W4 W3 W2 W1 W0 UN1 UN0 BCC ETX EOT
COMMANDS DATA
BLOCKS
COMMANDS
859715-25-35 en ma 2012-07