DI 2 Delay
d2d
- Input delay or alarm
delay
Sets delay of activation for the input configured.
DI 3 Polarity
i3P
- Digital input 3
polarity
CL
= The input is activated by closing the contact;
OP
= The input is
activated by opening the contact.
DI 3 Config
i3F
- Digital input 3
configuration
Selects 3rd Digital Input configuration for sequence. When set to Door
Switch, the device will obey E2 property setting
Door Sw Mode (odC
) and
shut down refrigeration and/or fan relay outputs, and resume normal
operation when door switch deactivates. If Door Switch stays in active
state for longer than
DI 1 DELAY (did)
setting, the device will alarm and
the refrigeration and/or fan relay outputs will turn back on if
DOOR ALM
RESTART (rrd)
is set to
YES
. The local display will show
dA
. When set to
Light Switch
, the change of state of the digital input will turn the light ON
or OFF, depending on how polarity and delay are set. If
Light Switch
is
chosen, the
Lights On
property of the Inputs tab has to be mapped
(pointed) as an input from the same application and its respective digital
input 3 output property in the Outputs tab. If set to
Device On/Off
, the
change of state of the digital input will turn the device ON or OFF,
depending on how polarity and delay are set. If
Device On/Off
is chosen,
the
Device Disable
property in the Inputs tab has to be mapped (pointed)
as an input from the same application and its respective digital input 3
output property in the Outputs tab. If
Set Point Shift
is chosen, the
SetPoint Shift
property in the Inputs tab has to be mapped (pointed) as
an input from the same application and its respective digital input 3
output property in the Outputs tab.
DI 3 Delay
d3d
- Input delay or alarm
delay
Sets delay of activation for the input configured.
LIGHTS ON
Command input of lights
on
Defaulted to fixed value of
ON
. This can be configured to use a pointer in
from another E2 application digital value output into this property as its
ON/OFF input to which will command the device light output relay to an
ON or OFF state.
Example
: Time schedule output can be pointed into this property as its
ON/OFF input which will command device light output relay.
DEFROST START
Command input of defrost
on
Defaulted to fixed value of
OFF
. This can be configured to use a pointer in
from another E2 application digital value output into this property as its
ON/OFF input to which will command the device into a defrost sequence.
Example
: Time schedule output can be pointed into this property as its
ON/OFF input which will command device into a defrost start sequence.
DEVICE DISABLE
Command input of device
disable
Defaulted to fixed value of
ON
. This can be configured to use a pointer in
from another E2 application digital value output into this property as its
ON/OFF input to which will command the device light output relay to an
ON or OFF state. An
OFF
command will turn the device off.
SETPOINT SHIFT
Command input of energy
savings
Defaulted to fixed value of
ON
. This can be configured to use a pointer in
from another E2 application digital value output into this property as its
ON/OFF input to which will command the device light output relay to an
ON or OFF state. An
OFF
command will turn the device off.
Defrost Synch
LMd
- LAN Defrost
synchronization
Not used.
Defr End Synch
dEM
- LAN Defrost
termination sync
Not used.
Set Point Synch
LSP
- LAN setpoint
synchronization
Not used.
Display Synch
LdS
- LAN display
synchronization
Not used.
Table 2 - XM670K_50 Property Help Explanations