Unidrive M702 User Guide
61
Issue Number: 3
Ensure cables used suit local wiring regulations.
Table 4-9 Cable ratings (200 V)
The nominal cable sizes below are only a guide. The mounting and grouping of cables affects their current-carrying capacity, in some cases
smaller cables may be acceptable but in other cases a larger cable is required to avoid excessive temperature or voltage drop. Refer to
local wiring regulations for the correct size of cables.
Model
Cable size (IEC)
mm
2
Cable size (UL)
AWG
Input
Output
Input
Output
Nominal Maximum
Nominal Maximum
Nominal Maximum
Nominal Maximum
03200050
1.5
4
1.5
4
14
10
14
10
03200066
03200080
4
4
12
12
03200106
04200137
6
8
6
8
10
8
10
8
04200185
8
8
8
8
05200250
10
10
10
10
8
8
8
8
06200330
16
25
16
25
4
3
4
3
06200440
25
25
3
3
07200610
35
70
35
70
2
1/0
2
1/0
07200750
1
1
07200830
70
70
1/0
1/0
08201160
95
2 x 70
95
2 x 70
3/0
2 x 1
3/0
2 x 1
08201320
2 x 70
2 x 70
2 x 1
2 x 1
NOTE
CAUTION
Содержание Unidrive M702