![Emerson Tartarini Dosaodor-D Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/emerson/tartarini-dosaodor-d/tartarini-dosaodor-d_instruction-manual_103332016.webp)
Before starting the calibration
procedure, the system must be
correctly installed and tested. Refer
to Type Dosaodor-D Software for
Configuration of Type Dosaodor-D
Odorant Injection System Manual
(D103117X012) for following
programming steps.
CAUTION
During the calibration procedure gas
overodorization or underodorization
may take place.
To avoid this, the calibration process
might be accomplished “off-line”
using simulation devices (Plastic tank
containing anti-freezing liquid). Please
contact your local Sales Office in case
off-line calibration is mandatory.
Put the system in Disable mode.
Select the injector to be calibrated. See Screenshot 1.
Screenshot 1: Injection System
Enter following data:
a) Odorant Injection Concentration (depending on
the odorant type). See Screenshot 2.
b) Entered Specific Volume for the Injector that must
be calibrated. See Screenshot 2.
Choose data from Table 3a or 3b (according to odorant
flow rate) and multiply this value for the odorant
Specific Gravity.
Definition:
Odorant Specific Gravity = ρodorant/ρH2O =
ρodorant/8.32
ρodorant = Odorant Density [LBS/Gal]
ρH2O = 8.32 LBS/Gal
Examples:
ρSulfur base odorant = 8.345 LBS/Gal
ρMercaptan base odorant = 6.776 LBS/Gal
Screenshot 2: Injection Data Configuration
c) Odorant Weight (depending on odorant type).
See Screenshot 3.
d) Rated Odorant Calibration Cylinder Capacity (see
proper value on pneumatic panel nameplate).
See Screenshot 3.
Screenshot 3: Injection Data Configuration
e) Manual Mode Gas Flow Rate. See Screenshot 4.
Choose data from Table 3a or 3b; if Injection
Concentration is different from 2.48 LBS/MMCF /
40 mg/m
3
, then calculate the new value by the formula
below.
Screenshot 4: Operating Data Configuration
If required
Injection Concentration
is different from
2.48 LBS/MMCF / 40 mg/m
3
then the
Manual Mode
Gas Flow Rate
value must be recalculated by the
following formula:
16