![Emerson Rosemount Oxymitter DR Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/emerson/rosemount-oxymitter-dr/rosemount-oxymitter-dr_reference-manual_103735060.webp)
Figure 4-3: Cell Replacement Kit
A. Probe tube (not included in kit)
B. Calibration gas passage
C. Socket head cap screws
D. Cell and flange assembly
E. Corrugated seal
Procedure
to remove the probe from the stack or
duct.
2. If the probe uses a snubber diffuser, use a spanner wrench to remove the flame
arrestor/snubber diffuser assembly.
3. Remove the locking set screw from the flame arrestor. Use spanner wrenches from
) to turn the flame arrestor hub free from the
probe flange. If equipped with the flame arrestor with ceramic diffuser, remove and
discard the setscrews and remove the vee deflector (
ceramic diffuser. If damaged, replace using the element.
Note
The flame arrestor and flame arrestor hub are among the critical components of
this type of protection. See
Safety Data Sheet 1A99078
.
Maintenance and service
Reference Manual
October 2019
00809-0100-4880
60
Emerson.com/Rosemount
Содержание Rosemount Oxymitter DR
Страница 1: ...Reference Manual 00809 0100 4880 Rev AB October 2019 Rosemount Oxymitter DR In Situ Oxygen Probe ...
Страница 4: ...4 ...
Страница 52: ...Startup and operate Reference Manual October 2019 00809 0100 4880 52 Emerson com Rosemount ...
Страница 66: ...Maintenance and service Reference Manual October 2019 00809 0100 4880 66 Emerson com Rosemount ...
Страница 72: ...Troubleshoot Reference Manual October 2019 00809 0100 4880 72 Emerson com Rosemount ...
Страница 74: ...Return material Reference Manual October 2019 00809 0100 4880 74 Emerson com Rosemount ...
Страница 84: ...Replacement parts Reference Manual October 2019 00809 0100 4880 84 Emerson com Rosemount ...
Страница 94: ...Declaration of Conformity Reference Manual October 2019 00809 0100 4880 94 Emerson com Rosemount ...
Страница 95: ...Reference Manual Declaration of Conformity 00809 0100 4880 October 2019 Rosemount Oxymitter DR 95 ...
Страница 96: ...Declaration of Conformity Reference Manual October 2019 00809 0100 4880 96 Emerson com Rosemount ...
Страница 97: ...E China RoHS table Reference Manual China RoHS table 00809 0100 4880 October 2019 Rosemount Oxymitter DR 97 ...