Membrane keypad available in five languages: English, French, German, Italian, and
Spanish.
An operator can communicate with the transmitter in one of three ways:
•
Membrane keypad
•
Local operator interface (LOI)
•
Optional HART
®
interface
1.2.5
Handling
1.2.6
System considerations
Prior to installing your transmitter, make sure you have all the components necessary to
make the system installation. Ensure all components are properly integrated to make the
system functional.
After verifying that you have all the components, select mounting locaqtions and
determine how each component will be placed in terms of available line voltage, ambient
temperatures, environmental considerations, convenience, and serviceability.
shows a typical system installation.
Figure 1-2: Typical System Installation
Instrument air for reference air is optional for most applications. Ambient air passively
diffuses into the inside of the probe in sufficient quantity for an accurate measurement.
Instrument air is required for applications where the ambient air at the probe location may
not contain the typical 20.95 percent O
2
. An example would be an installation into a
positive pressure flue gas duct which has many leakes into the surrounding air.
If the calibration gas bottles will be permanently connected, use a blocking valve or check
valve next to the calibration fittings on the termination housing. This blocking valve or
check valve is to prevent breathing of the calibration gas line and subsequent flue gas
condensation and corrosion.
Note
Keep the packaging in which the transmitter arrived from the factory in case you need to
ship any components to another site. Emerson has designed this packaging to protect the
product.
1.2.7
Upgrading the Rosemount
™
Oxymitter 4000
You can easily upgrade the Rosemount Oxymitter 4000 to a full Oxymitter 4000 or 5000.
This provides an economical upgrade path for customers looking to preserve their probe
investment upon the eventual failure of the signal conditioning electronics. To upgrade,
add a small electronics package to the existing termination housing of the probe. The
converted unit will be a full Rosemount Oxymitter 4000 or 5000 Oxygen Transmitter that
can provide a 4-20 mA oxygen signal without an external signal conditioning electronics
package. The Rosemount Oxymitter electronics comes with HART
®
or F
OUNDATION
™
Reference Manual
Description and specifications
00809-0100-4880
October 2019
Rosemount Oxymitter DR
17
Содержание Rosemount Oxymitter DR
Страница 1: ...Reference Manual 00809 0100 4880 Rev AB October 2019 Rosemount Oxymitter DR In Situ Oxygen Probe ...
Страница 4: ...4 ...
Страница 52: ...Startup and operate Reference Manual October 2019 00809 0100 4880 52 Emerson com Rosemount ...
Страница 66: ...Maintenance and service Reference Manual October 2019 00809 0100 4880 66 Emerson com Rosemount ...
Страница 72: ...Troubleshoot Reference Manual October 2019 00809 0100 4880 72 Emerson com Rosemount ...
Страница 74: ...Return material Reference Manual October 2019 00809 0100 4880 74 Emerson com Rosemount ...
Страница 84: ...Replacement parts Reference Manual October 2019 00809 0100 4880 84 Emerson com Rosemount ...
Страница 94: ...Declaration of Conformity Reference Manual October 2019 00809 0100 4880 94 Emerson com Rosemount ...
Страница 95: ...Reference Manual Declaration of Conformity 00809 0100 4880 October 2019 Rosemount Oxymitter DR 95 ...
Страница 96: ...Declaration of Conformity Reference Manual October 2019 00809 0100 4880 96 Emerson com Rosemount ...
Страница 97: ...E China RoHS table Reference Manual China RoHS table 00809 0100 4880 October 2019 Rosemount Oxymitter DR 97 ...