of up to four Rosemount Oxymitter 4000s to accommodate automatic and semi-
automatic calibration routines.
Figure B-2: Rosemount IMPS 4000
The sequencer works in conjunction with the CALIBRATION RECOMMENDED feature,
eliminating out-of-calibration occurrences and the need to send a technician to the
installation site. In addition, the Rosemount IMPS 4000 provides a remote contact input to
initiate a calibration from a remote location and relay outputs to alert when a calibration is
in progress, an O
2
probe is out of calibration, calibration gases are on, or calibration
pressure is low.
B.3
Rosemount
™
SPS 4001B Single Probe
Autocalibration Sequencer
Emerson specifically designed the Rosemount SPS 4001B Single Probe Autocalibration
Sequencer to perform automatic or on-demand calculations.
The Rosemount SPS 40001B system must be installed in a remote, safe area if the
Rosemount Oxymitter 4000 is installed in a hazardous area.
The Rosemount SPS 4001B works in conjunction with the Rosemount Oxymitter 4000,
eliminating out-of-calibration occurrences and the need to send a technician to the
installation site.
Optional accessories
Reference Manual
October 2019
00809-0100-4340
182
Emerson.com/Rosemount
Содержание Rosemount Oxymitter 4000
Страница 4: ...4 ...
Страница 8: ...Contents Reference Manual October 2019 00809 0100 4340 viii Emerson com Rosemount ...
Страница 84: ...Configure transmitter with LOI Reference Manual October 2019 00809 0100 4340 84 Emerson com Rosemount ...
Страница 110: ...HART AMS Reference Manual October 2019 00809 0100 4340 110 Emerson com Rosemount ...
Страница 114: ...HART AMS Reference Manual October 2019 00809 0100 4340 114 Emerson com Rosemount ...
Страница 184: ...Optional accessories Reference Manual October 2019 00809 0100 4340 184 Emerson com Rosemount ...
Страница 188: ...Safety data sheet for ceramic fiber products Reference Manual October 2019 00809 0100 4340 188 Emerson com Rosemount ...
Страница 192: ...Rosemount Oxymitter product certifications Reference Manual October 2019 00809 0100 4340 192 Emerson com Rosemount ...
Страница 194: ...Declaration of Conformity Reference Manual October 2019 00809 0100 4340 194 Emerson com Rosemount ...
Страница 195: ...Reference Manual Declaration of Conformity 00809 0100 4340 October 2019 Rosemount Oxymitter 4000 195 ...
Страница 196: ...Declaration of Conformity Reference Manual October 2019 00809 0100 4340 196 Emerson com Rosemount ...
Страница 197: ...G China RoHS table Reference Manual China RoHS table 00809 0100 4340 October 2019 Rosemount Oxymitter 4000 197 ...