Quick Installation Guide
00825-0500-4809, Rev CA
September 2003
Threaded Flo-Tap 485 Annubar
S
TEP
8
CONTINUED
...
Figure 11. Valve Identification for 5-valve and 3-Valve Manifolds
Table 3. Description of Impulse Valves and Components
5-Valve Manifold
3-Valve Manifold
Name
Description
Purpose
Components
1
Electronics
Reads Differential Pressure
2
Manifold
Isolates and equalizes electronics
Manifold and Impulse Valves
PH
Primary Sensor
(1)
(1) High Pressure
High and low side pressure process
connections.
PL
Primary Sensor
(2)
(2) Low Pressure
DVH
Drain/Vent Valve
(1)
Drains (for gas service) or vents (for liquid or
steam service) the DP electronics chambers
DVL
Drain/Vent Valve
(2)
MH
Manifold
(1)
Isolates high side or low side pressure from the
process
ML
Manifold
(2)
MEH
Manifold Equalizer
(1)
Allows high and low pressure side access to
the vent valve, or for isolating the process fluid
MEL
Manifold Equalizer
(2)
ME
Manifold Equalizer
Allows high and low side pressure to equalize
MV
Manifold Vent Valve
Vents process fluid
To PH
To PL
MH
MV
ML
DVL
DVH
MEL
MEH
2
1
To PH
To PL
MH
ME
ML
DVL
DVH
2
1
4809-0500 Rev CA.fm Page 16 Monday, September 22, 2003 11:14 AM