Quick Installation Guide
00825-0500-4809, Rev CA
September 2003
Threaded Flo-Tap 485 Annubar
S
TEP
7
CONTINUED
...
Gear Drive (G)
1.
Open the isolation valve fully.
2. Rotate the crank clockwise. If a power drill with an adapter is used,
do not exceed 200 rpm.
a. Continue rotating the crank until the sensor firmly contacts the
opposite side of the pipe. The orange stripes are visual
indication of when the sensor is approaching the opposite side
wall.
b. As the orange stripes approach the support plate, remove the
power drill and continue cranking manually. Place a finger above
the packing gland while cranking. When movement stops, the
sensor is in contact with the opposite side wall.
c. Turn the handle an additional
1
/
4
- to
1
/
2
-in. to secure the sensor.
3. Secure the drive by inserting the drive lock pin as shown in
Figure 10.
Figure 10. Insert the Sensor
Standard Drive (M)
Gear Drive (G)
Drive
Lock
Pin