Only suppress echoes which can be clearly identified as objects in the tank. Compare
the list of interfering echoes with the tank drawing or visual inspection of the tank.
•
Do not suppress false echoes located below the product surface.
•
Keep the number of suppressed false echoes to a minimum.
It is recommended to suppress false echoes using Rosemount Radar Master Plus.
Procedure
1. Select
Service Tools
→
Echo Curve
.
2. In the echo curve, click at the unknown echo peak, and then select
Suppress
.
Figure 7-21: Add False Echo Suppression
Postrequisites
It may be necessary to suppress new false echoes at a later stage when objects have
become visible due to surface movement.
Related information
Delete a false echo suppression
Prerequisites
It is recommended to suppress false echoes using Rosemount Radar Master Plus.
Procedure
1. Select
Service Tools
→
Echo Curve
.
Reference Manual
Service and troubleshooting
00809-0100-4418
September 2022
Rosemount 3408 Level Transmitter
97
Содержание Rosemount 3408
Страница 4: ...4 ...
Страница 14: ...Transmitter overview Reference Manual September 2022 00809 0100 4418 14 Emerson com Rosemount ...
Страница 28: ...Mechanical installation Reference Manual September 2022 00809 0100 4418 28 Emerson com Rosemount ...
Страница 38: ...Electrical installation Reference Manual September 2022 00809 0100 4418 38 Emerson com Rosemount ...
Страница 46: ...Configuration Reference Manual September 2022 00809 0100 4418 46 Emerson com Rosemount ...
Страница 54: ...Operation and maintenance Reference Manual September 2022 00809 0100 4418 54 Emerson com Rosemount ...
Страница 104: ...Service and troubleshooting Reference Manual September 2022 00809 0100 4418 104 Emerson com Rosemount ...