Reference Manual
00809-0100-4716, Rev JA
May 2008
Rosemount 3095 MultiVariable
5-12
5.
Follow these steps to install the drain/vent valve:
a. Apply sealing tape to the threads on the seat. Starting at the base
of the valve with the threaded end pointing toward the installer,
apply two clockwise turns of the sealing tape.
b. Take care to orient the opening on the valve so that process fluid
will drain toward the ground and away from personnel when the
valve is opened.
c. Tighten the drain/vent valve to 250 in-lb.
EA ERROR MESSAGE
SUMMARY
Warning Messages
The EA warns the operator whenever an action could change the analog
output:
The EA also warns the operator at the conclusion of an action that may have
changed the analog output: