Figure C-5: Example of Range Value Settings
B
E
C
D
A
A. Reduced accuracy zone
B. 100% (20 mA)
C. Zero Level
D. Level measurement range 0-100%
E. 0% (4 mA)
Related information
C.4.3
Alarm mode
The transmitter automatically and continuously performs self-diagnostic routines. If a
failure or a measurement error is detected, the transmitter drives the output to selected
alarm limit (high or low).
C.4.4
Analog alarm limits
High/low alarm value
The high/low alarm current for the analog output when the device enters the alarm mode.
Related information
High/low saturation value
The device will continue to set a current that corresponds with the measurement until
reaching the upper/lower limit (and then freeze).
Configuration parameters
Reference Manual
May 2021
00809-0200-4480
84
Rosemount 1408A Level and Flow Transmitter