Table 1-1. Product Matrix - Hazardous Area OCX 8800
OCX88C
O
2
/Combustibles Transmitter - Flameproof
Code
Probe Length and Material
00
No Probe or Exhaust Tube
11
18 in. (457 mm) 316 SST
up to 1300°F (704°C)
21
18 in. (457 mm) Inconel 600
up to 2600°F (1427°C)
31
18 in. (457 mm) Ceramic
up to 2600°F (1427°C)
12
3 ft (0.91 m) 316 SST
up to 1300°F (704°C)
22
3 ft (0.91 m) Inconel 600
up to 1832°F (1000°C)
32
3 ft (0.91 m) Ceramic
up to 2600°F (1427°C)
13
6 ft (1.83 m) 316 SST
up to 1300°F (704°C)
23
6 ft (1.83 m) Inconel 600
up to 1832°F (1000°C)
14
9 ft (2.7 m) 316 SST
up to 1300°F (704°C)
24
9 ft (2.7 m) Inconel 600
up to 1832°F (1000°C)
Code
Probe Mounting Assembly
10
(ANSI 2 in. 150 lb) 6" dia. flange, 4.75" BC with 4 x 0.75" dia. holes
20
(DIN) 185 mm dia. flange, 145 mm BC with 4 x 18 mm dia. holes
Code
Mounting Hardware - Stack Side
0
No Adapter Plate (“0” must be chosen under “Mounting Adapter - Probe Side” below)
1
New Installation - Square weld plate with studs
2
Model 218/240 Mounting Plate (with Model 218/240 Shield Removed)
3
Existing Model 218/240 Support Shield
4
Special Mounting
(1)
5
Model 132 Adapter Plate
Code
Mounting Hardware - Probe Side
0
No Adapter Plate
1
Probe Only (ANSI)
2
Probe Only (DIN)
Code
Electronics Housing - Communications
H1
HART Communications
(2)
H2
HART Communications with LOI
H3
HART Communications with Calibration Solenoids
(2)
H4
HART Communications with LOI and Calibration Solenoids
Code
Electronics Mounting
02
Remote Electronics and no cable
Code
Accessories
00
None
01
Flow meters & Ref. Air Set
02
In-Situ Filter (Stainless Steel only)
03
In-Situ Filter (SST), Flow meters & Ref. Air Set
11
Flow meters, and Ref. Air Set with Blowback
12
In-Situ Filter (SST) with Blowback
13
In-Situ Filter (SST), Flow meters & Ref. Air Set with Blowback
OCX88C
11
10
1
1
H2
02
02
Example
NOTES:
(1)
Provide details of the existing mounting plate as follows:
Plate with studs
Bolt circle diameter, number, and arrangement of studs, stud thread, stud height above mounting plate.
Plate without studs
Bolt circle diameter, number, and arrangement of holes, thread, depth of stud mounting plate with accessories.
(2)
If the LOI is not implemented, remote access and functionality available via HART Communications (Model 275/375 Handheld Communicator)
with Oxygen/Combustibles Device Description (DD) required.
Содержание OCX 8800
Страница 2: ......
Страница 4: ......
Страница 25: ...Instruction Manual IM 106 880 Rev 1 0 January 2007 2 5 OCX 8800 Figure 2 2 Adapter Plate Installation ...
Страница 50: ...Instruction Manual IM 106 880 Rev 1 0 January 2007 OCX 8800 4 10 ...
Страница 70: ...Instruction Manual IM 106 880 Rev 1 0 January 2007 OCX 8800 6 10 ...
Страница 114: ...Instruction Manual IM 106 880 Rev 1 0 January 2007 OCX 8800 8 12 ...
Страница 124: ...Instruction Manual IM 106 880 Rev 1 0 January 2007 OCX 8800 9 10 ...
Страница 156: ...Instruction Manual IM 106 880 Rev 1 0 January 2007 OCX 8800 A 32 ...
Страница 164: ...Instruction Manual IM 106 880 Rev 1 0 January 2007 OCX 8800 C 2 ...