Mentor MP User Guide
53
Issue: 3 www.controltechniques.com
24
Digital I/O 1
25
Digital I/O 2
26
Digital I/O 3
Terminal 24 default function
AT SPEED output
Terminal 25 default function
DRIVE RESET input
Terminal 26 default function
RUN FORWARD input
Type
Positive or negative logic digital inputs,
positive or negative logic push-pull outputs
or open collector outputs
Input / output mode controlled by... Pr
8.31
, Pr
8.32
and Pr
8.33
Operating as an input
Logic mode controlled by...
Pr
8.29
Absolute maximum applied voltage
range
+
30V, -18V relative to 0V
Impedance
6k
Ω
Input thresholds
10.0V
±
0.8V
Operating as an output
Open collector outputs selected
Pr
8.30
Nominal maximum output current
200mA (total including terminal 22)
Maximum output current
240mA (total including terminal 22)
Common to all modes
Voltage range
0V to +24V
Sampling period
250
μ
s if configured with the destination as
Pr
6.35
or Pr
6.36
. 4ms for all other
destinations
27
Digital input 4
28
Digital input 5
29
Digital input 6
Terminal 27 default function
RUN REVERSE input
Terminal 28 default function
LOCAL/REMOTE select
Terminal 29 default function
JOG SELECT input
Type of input
Negative or positive logic digital inputs
Logic mode controlled by...
Pr
8.29
Voltage range
0V to +24V
Absolute maximum applied voltage
range
+30V, -18V relative to 0V
Impedance
6k
Ω
Input thresholds
10.0V
±
0.8V
Sampling period
250
μ
s if configured with the destination as
Pr
6.35
or Pr
6.36
. 4ms for all other
destinations
30
0V common
Function
Common connection for all external
devices
31
ENABLE
Function
Drive enable
Type
Positive or negative logic digital input
Absolute maximum applied voltage
range
+30V, -18V relative to 0V
Input threshold
10.0V
±
0.8V
Sampling period
4ms
Drive commissioning output
Function
Instantaneous armature current
feedback
Type of output
Unipolar single-ended voltage
Full scale voltage range
10V ±5%
Maximum offset
7mV
Protection
~25mA max. Short circuit protection to
ground (0V).
Model
Full scale range of drive
commisioning output
MP25A4(R)
MP25A5(R)
2.29 x Drive rated current
(Pr
11.32
)
MP45A4(R)
MP45A5(R)
2.30 x Drive rated current
(Pr
11.32
)
MP75A4(R)
MP75A5(R)
2.42 x Drive rated current
(Pr
11.32
)
MP105A4(R)
MP105A5(R)
2.29 x Drive rated current
(Pr
11.32
)
MP155A4(R)
MP155A5(R)
2.30 x Drive rated current
(Pr
11.32
)
MP210A4(R)
MP210A5(R)
2.41 x Drive rated current
(Pr
11.32
)
MP350A4(R)
MP350A5(R)
MP350A6(R)
2.73 x Drive rated current
(Pr
11.32
)
MP420A4(R)
2.27 x Drive rated current
(Pr
11.32
)
MP470A5(R)
MP470A6(R)
3.34 x Drive rated current
(Pr
11.32
)
MP550A4(R)
2.85 x Drive rated current
(Pr
11.32
)
MP700A4(R)
MP700A5(R)
MP700A6(R)
2.24 x Drive rated current
(Pr
11.32
)
MP825A4(R)
MP825A5(R)
MP825A6(R)
2.46 x Drive rated current
(Pr
11.32
)
MP900A4(R)
2.25 x Drive rated current
(Pr
11.32
)
MP1200A4(R) MP1200A5(R) MP1200A6(R)
3.44 x Drive rated current
(Pr
11.32
)
MP1850A4(R) MP1850A5(R) MP1850A6(R)
2.23 x Drive rated current
(Pr
11.32
)
41
Tachogenerator positive input
42
Tachogenerator negative input
Function
Speed feedback inputs for
tachogenerator feedback device
Maximum voltage
300V
Feedback scaling controlled by
Pr
3.51
(
Fb02, 0.72
)
Sampling period
4ms
Status relay contacts are over-voltage category II.
A fuse or other over-current protection should be installed to
the relay circuit.
WARNING
WARNING
Содержание MP105A4