106
Mentor MP User Guide
www.controltechniques.com Issue: 3
Parameter
Range(
Ú
)
Default(
Ö
)
Type
4.01
Current magnitude
{di08, 0.43}
±DRIVE_CURRENT_MAX A
RO Uni FI NC PT
4.02
Filtered current magnitude
RO Uni FI NC PT
4.03
Torque demand
{di07, 0.42}
±TORQUE_PROD_CURRENT_MAX %
RO Bi
FI NC PT
4.04
Current demand
RO Bi
FI NC PT
4.05
Motoring current limit
0 to MOTOR1_CURRENT_LIMIT_MAX %
150.0
RW Uni
RA
US
4.06
Regen current limit
RW Uni
RA
US
4.07
Symmetrical current limit
RW Uni
RA
US
4.08
Torque reference
±USER_CURRENT_MAX %
0.00
RW Bi
US
4.09
Torque offset
0.0
RW Bi
US
4.10
Torque offset select
OFF (0) or On (1)
OFF (0)
RW Bit
US
4.11
Torque mode selector
0 to 4
0
RW Uni
US
4.12
Current demand filter 1
0.0 to 25.0 ms
6.0
RW Uni
US
4.13
Continuous current controller Kp gain
0 to 4,000
100 RW Uni
RA
US
4.14
Continuous current controller Ki gain
50 RW Uni
RA
US
4.15
Thermal time constant
0 to 3000.0
89.0
RW Uni
US
4.16
Thermal protection mode
0 to 1
0
RW Bit
US
4.18
Overriding current limit
0 to TORQUE_PROD_CURRENT_MAX %
RO Uni
NC PT
4.19
Overload accumulator
0 to 100.0 %
RO Uni
NC PT
4.20
Percentage load
±USER_CURRENT_MAX %
RO Bi
FI NC PT
4.22
Inertia compensation enable
OFF (0) or On (1)
OFF (0)
RW Bit
US
4.23
Current demand filter 2
0.0 to 25.0 ms
6.0
RW Uni
US
4.24
User current maximum scaling
0.0 to TORQUE_PROD_CURRENT_MAX %
150.0
RW Uni
RA
US
4.27
Current taper 1 threshold
0 to 10,000.0 rpm
10,000.0 rpm
RW Uni
US
4.28
Current taper 2 threshold
RW Uni
US
4.29
Current taper 1 end point
0 to 1000.0%
1000.0%
RW Uni
US
4.30
Current taper 2 end point
RW Uni
US
4.31
Taper threshold 1 exceeded
OFF (0) or On (1)
RO Bit
4.32
Taper threshold 2 exceeded
RO Bit
4.33
Slew rate limit
0.0 to 60,000 %s
-1
7000
RW Uni
US
4.34
Discontinuous current controller Ki gain
0 to 4,000
200
RW Uni
RA
US
4.35
Extra safe bridge change
OFF (0) or On (1)
OFF (0)
RW Bit
US
4.36
Reduced hysteresis for bridge change
over
RW Bit
US
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save