11.22.1 Reference modes
* Setting Pr
1.15
to 9 enables the Preset reference scan timer. With the
scan timer enabled analog 1 and preset references 2 to 8 are selected
automatically in turn. Pr
1.16
defines the time between each change.
** Jog forward can only be selected when the drive is in either the ready
(rdy), inhibit (inh) or trip states.
Preset references
Preset references 1 to 8 are contained in Pr
1.21
to Pr
1.28
.
Keypad reference
If Keypad reference is selected the drive sequencer is controlled directly
by the keypad keys and the keypad reference parameter (Pr
1.17
) is
selected. The sequencing bits, Pr
6.30
to Pr
6.34
, and Pr
6.37
have no
effect and jog is disabled.
Precision reference
If Precision reference is selected the speed reference is given Pr
1.18
and Pr
1.19
.
Reference modes
Pr
1.14
(
SE05, 0.26
), Pr
1.15
S ramps
Pr
2.06
and Pr
2.07
Torque modes
Pr
4.08
and Pr
4.11
Current limit tapers
Pr
4.27
, Pr
4.28
,
Pr
4.29
,
Pr
4.30
,
Pr
4.31
, Pr
4.32
Start/stop logic modes
Pr
6.04
and Pr
6.40
Catch a spinning motor
Pr
6.09
Position modes
Pr
13.10
1.14
(SE05, 0.26)
Reference selector
RW
Txt
NC
US
Ú
A1.A2 (0), A1.Pr (2), A2.Pr (2),
Pr (3), PAd (4), Prc (5),
Pad rEF (6)
Ö
A1.A2 (0)
1.15
Preset reference selector
RW
Uni
NC
US
Ú
0 to 9
Ö
0
Table 11-5 Active reference
Pr 1.14
(
SE05, 0.26
)
Pr 1.15
Digital input T28
Digital input T29
Pr 1.49
Pr 1.50
Active reference
State
Function
State
Function
A1.A2
(0)
0 or 1
0
Local Remote
Jog forward**
1
1
Analog input 1
1
2
1
Analog input 2
2 to 8
No function
1 or 2
2 to 8
Preset reference 2 to 8
9 *
0
Local Remote
1
1
Analog input 1
1
2
1
Analog input 2
No function
1 or 2
2 to 8
Preset reference 2 to 8
A1.Pr
(1)
0
0
Preset select bit 0
0
Preset select bit 1
1
1
Analog input 1
1
2
Preset reference 2
0
1
3
Preset reference 3
1
4
Preset reference 4
1
No function
No function
1
Analog input 1
2 to 8
2 to 8
Preset reference 2 to 8
9 *
1
Analog input 1
2 to 8
Preset reference 2 to 8
A2.Pr
(2)
0
0
Preset select bit 0
0
Preset select bit 1
2
1
Analog input 2
1
2
Preset reference 2
0
1
3
Preset reference 3
1
4
Preset reference 4
1
No function
No function
1
Analog input 2
2 to 8
2 to 8
Preset reference 2 to 8
9 *
1
Analog input 2
2 to 8
Preset reference 2 to 8
Pr
(3)
0
0
Preset select bit 0
0
Preset select bit 1
3
1
Preset reference 1
1
2
Preset reference 2
0
1
3
Preset reference 3
1
4
Preset reference 4
1 to 8
No function
No function
1 to 8
Preset reference 1 to 8
9 *
1 to 8
Preset reference 1 to 8
PAd
(4)
No function
No function
4
Keypad reference
Prc
(5)
No function
No function
5
Precision reference
Pad rEF
(6)
No function
Jog forward**
6
Keypad reference
Содержание MP105A4