6
Mentor MP User Guide
www.controltechniques.com Issue: 3
2 Product information
Table 2-1 Model to frame size cross reference
2.1 Ratings
The power ratings for the 480V, 575V and 690V configurations are
shown in Table 2-2, Table 2-3 and Table 2-4.
The continuous current ratings given are for a maximum ambient
temperature of 40°C (104°F) and an altitude of 1000m. For operation at
higher temperatures and altitudes de-rating is required.
For further information see Chapter 12
Table 2-2 480V current ratings
Table 2-3 575V current ratings
* For this rating at 575V, 150% overload time is 20s at 40
°
C and 30s at
35
°
C.
Table 2-4 690V current ratings
* For this rating at 690V, 150% overload time is 20s at 40
°
C and 30s at
35
°
C.
Maximum continuous input current
The values of maximum continuous input current are given to aid the
selection of cables and fuses. These values are stated for worst-case
condition.
For current ratings above 1850A then parallel connection of the drives is
required. However, this function is not implemented on firmware
versions V01.05.00 and earlier.
Model
Frame
480V
EN/IEC
cULus
575V
EN/IEC
cULus to 600V
690V
EN/IEC
MP25A4(R)
MP25A5(R)
1A
MP45A4(R)
MP45A5(R)
MP75A4(R)
MP75A5(R)
MP105A4(R)
MP105A5(R)
1B
MP155A4(R)
MP155A5(R)
MP210A4(R)
MP210A5(R)
MP350A4(R)
MP350A5(R)
MP350A6(R)
2A
MP420A4(R)
MP470A5(R)
MP470A6(R)
MP550A4(R)
MP700A4(R) MP700A5(R)
MP700A6(R)
2B
MP825A4(R)
MP825A5(R)
MP825A6(R)
MP900A4(R)
MP1200A4
MP1200A5
MP1200A6
2C
MP1850A4
MP1850A5
MP1850A6
MP1200A4R
MP1200A5R
MP1200A6R
2D
MP1850A4R
MP1850A5R
MP1850A6R
Model
AC input
current
DC output current
Typical motor
power
Continuous Continuous
150%
overload
@
400Vdc
@
500Vdc
A
A
A
kW
hp
MP25A4(R)
22
25
37.5
9
15
MP45A4(R)
40
45
67.5
15
27
MP75A4(R)
67
75
112.5
27
45
MP105A4(R)
94
105
157.5
37.5
60
MP155A4(R)
139
155
232.5
56
90
MP210A4(R)
188
210
315
75
125
MP350A4(R)
313
350
525
125
200
MP420A4(R)
376
420
630
150
250
MP550A4(R)
492
550
825
200
300
MP700A4(R)
626
700
1050
250
400
MP825A4(R)
738
825
1237.5
300
500
MP900A4(R)
805
900
1350
340
550
MP1200A4(R)
1073
1200
1800
450
750
MP1850A4(R)
1655
1850
2775
700
1150
Model
AC input
current
DC output current
Typical motor
power
(With Vdc =
630V)
Continuous Continuous
150%
overload
A
A
A
kW
hp
MP25A5(R)
22
25
37.5
14
18
MP45A5(R)
40
45
67.5
25
33
MP75A5(R)
67
75
112.5
42
56
MP105A5(R)
94
105
157.5
58
78
MP155A5(R)
139
155
232.5
88
115
MP210A5(R)
188
210
315
120
160
MP350A5(R)
313
350
525
195
260
MP470A5(R)
420
470*
705
265
355
MP700A5(R)
626
700
1050
395
530
MP825A5(R)
738
825*
1237.5
465
620
MP1200A5(R)
1073
1200
1800
680
910
MP1850A5(R)
1655
1850
2775
1045
1400
Model
AC input
current
DC output Current
Typical motor
power (With
Vdc = 760V)
Continuous Continuous
150%
Overload
A
A
A
kW
hp
MP350A6(R)
313
350
525
240
320
MP470A6(R)
420
470*
705
320
425
MP700A6(R)
626
700
1050
480
640
MP825A6(R)
738
825*
1237.5
650
850
MP1200A6(R)
1073
1200
1800
850
1150
MP1850A6(R)
1655
1850
2775
1300
1750
NOTE