If the Status LED is off, the Signal Input module is being ignored by the 6560 Processor
module. This is a special case which should not be encountered in practice. Modules are
only ignored if the addition of the module would exceed the maximum channel count
limits that the 6560 Processor module can support (24 analog, 4 Tach, 4 I/O). Channels are
counted starting in the left-most.
Signal Input Module status conditions
Table A-8:
LED Color
Status
Priority Comments
Blinking Green
In POST
1
Typically only seen during system startup. Indicates
that POST (Power On Self Test) is being performed,
which involves Processor board resources.
Solid Red
Failure
2
Power supply POST failure, or other hardware
failure on processor board.
Alternating Red/
Green
Uncalibrated
3
One or more channels are uncalibrated.
Solid Green
OK
4
Normal operation.
Transient Filter Board specifications
Transient Filter Board specifications
Table A-9:
Number of channels
12
Filter type
8th order elliptic low pass
Filter passband frequency
DC to 2 kHz
Attenuation
80 dB
Passband ripple
<1 dB
Stop band frequency
3.12 kHz
Specifications
82
MHM-97453, Rev 1
Содержание Machinery Health Expert CSI 2600
Страница 1: ...User Guide MHM 97453 Rev 1 April 2014 CSI 2600 Machinery Health Expert User Guide ...
Страница 8: ...CSI 2600 back view Figure 2 2 Introduction to the CSI 2600 4 MHM 97453 Rev 1 ...
Страница 12: ...Introduction to the CSI 2600 8 MHM 97453 Rev 1 ...
Страница 26: ...Getting started 22 MHM 97453 Rev 1 ...
Страница 64: ...Software configuration 60 MHM 97453 Rev 1 ...
Страница 96: ...Data types 92 MHM 97453 Rev 1 ...
Страница 100: ...D 2 Internal wiring diagram for the CSI 2600 ...
Страница 106: ...Troubleshooting 102 MHM 97453 Rev 1 ...
Страница 109: ...Index MHM 97453 Rev 1 105 ...