![Emerson Machinery Health Expert CSI 2600 Скачать руководство пользователя страница 80](http://html.mh-extra.com/html/emerson/machinery-health-expert-csi-2600/machinery-health-expert-csi-2600_user-manual_103529080.webp)
Input Power LED
The Input Power LED indicates the status of the power converters that distribute various
voltages within the 6560 Processor module. A steady green color indicates that all power
converters are within the proper voltage ranges, while a steady or blinking red condition
indicates a power fault somewhere inside the 6560 Processor module.
CPU Status LED
The CPU Status LED indicates the status of the Main Processor board. The four status
conditions are listed in
along with their assigned priorities.
More than one status condition may be active at one time. When this happens, the LED will
indicate the active status condition with the highest priority. For example, if the module is
both
Uncalibrated
(Priority 3) and is also currently
In POST
(Priority 1), the LED would indicate
In POST
.
CPU status conditions
Table A-5:
LED Color
Status
Priority Comments
Blinking Green
In POST
1
Typically only seen during system startup. Indicates
that POST (Power On Self Test) is being performed,
which involves Processor board resources.
Solid Red
Failure
2
Power supply POST failure, or other hardware
failure on processor board.
Alternating Red/
Green
Uncalibrated
3
The onboard Test Function generator is
uncalibrated.
Solid Green
OK
4
Normal operation.
Transient Status LED
The Transient Status LED indicates the status of the Transient Daughterboard. The LED is
always off when a Transient board is not installed in the system. The four status conditions
are listed in
with their assigned priorities.
More than one status condition may be active at one time. When this happens, the LED will
indicate the active status condition with the highest priority.
Transient Daughterboard status conditions
Table A-6:
LED Color
Status
Priority Comments
Blinking Green
In POST
1
Typically only seen during system startup. Indicates
that POST (Power On Self Test) is being performed,
which involves Processor board resources.
Solid Red
Failure
2
Power supply POST failure, or other hardware
failure on processor board.
Alternating Red/
Green
Uncalibrated
3
One or more Transient channels are uncalibrated.
Specifications
76
MHM-97453, Rev 1
Содержание Machinery Health Expert CSI 2600
Страница 1: ...User Guide MHM 97453 Rev 1 April 2014 CSI 2600 Machinery Health Expert User Guide ...
Страница 8: ...CSI 2600 back view Figure 2 2 Introduction to the CSI 2600 4 MHM 97453 Rev 1 ...
Страница 12: ...Introduction to the CSI 2600 8 MHM 97453 Rev 1 ...
Страница 26: ...Getting started 22 MHM 97453 Rev 1 ...
Страница 64: ...Software configuration 60 MHM 97453 Rev 1 ...
Страница 96: ...Data types 92 MHM 97453 Rev 1 ...
Страница 100: ...D 2 Internal wiring diagram for the CSI 2600 ...
Страница 106: ...Troubleshooting 102 MHM 97453 Rev 1 ...
Страница 109: ...Index MHM 97453 Rev 1 105 ...