10
Scalding Hazard:
Do not allow
water to boil. May result in
severe burns.
Factory temperature
pre-
s
et i
s
190
˚F.
Di
s
connect power
from unit.
To adju
s
t water
temperature you’ll
need to acce
ss
the panel on the front of
the tan
k
. U
s
ing a
s
crewdriver, turn
thermo
s
tat
s
crew cloc
k
wi
s
e to increa
s
e
temperature or turn counter cloc
k
wi
s
e to
decrea
s
e temperature. The cover mu
s
t
alway
s
be in place for the thermo
s
tate to
re
s
pond properly.
After adju
s
ting, depre
ss
the di
s
pen
s
er
handle for 20
s
econd
s
for the water to
re-heat to the new
s
etting. If temperature
s
till i
s
not to your li
k
ing, repeat the procedure
ma
k
ing
s
ure that the handle i
s
depre
ss
ed
for 20
s
econd
s
.
Regularly in
s
pect the unit for any
s
ign
s
of
lea
k
age. If there are
s
ign
s
of water damage,
immediately remove the unit from
s
ervice.
To avoid water damage from lea
k
age,
replace all cut, loo
s
e or
s
plit tubing
.
A drain pan, plumbed to an appropriate
drain or outfitted with a lea
k
detector,
s
hould be u
s
ed in tho
s
e application
s
where
any lea
k
age could cau
s
e property damage.
PROPERTY DAMAGE
CARE AND USE
ADJUSTING THE THERMOSTAT
Only u
s
e mild cleaner
s
to clean the faucet
and pla
s
tic component
s
.
Cleaner
s
with acid
s
, abra
s
ive
s
, al
k
aline
or organic
s
olvent
s
will re
s
ult in deterioration
of the pla
s
tic component
s
and void
the warranty.
CLEANING THE FAUCET AND TANK
Anytime the instant hot water dispenser is not used
for extended periods of time, unplug and drain unit.
If it is below freezing you will need to unplug the
unit and drain it.
Di
s
connect power from unit.
Pu
s
h hot water di
s
pen
s
er faucet lever
and allow water to flow until it i
s
cool.
Shut the cold water flow off at the
s
hut off valve.
Remove unit from
s
in
k
and turn up
s
ide
down to drain.
SEASONAL STORAGE/DRAINAGE
11
Property Damage:
To avoid water damage, replace any loose or split tubing.
Periodically inspect the unit for any signs of leakage and immediately remove from
service any unit suspected of leaking.
Personal Injury:
This tank is a non-pressurized tank. DO NOT modify this system.
DO NOT close vent tube or connect other type dispensers or valves to the tank. Use only
the InSinkErator dispenser faucet supplied. Use only parts provided. Contact an
authorized InSinkErator Service agent for repairs or replacement components.
1-Year Warranty
Cover
s
all replacement part
s
and labor to correct defect
s
in material or wor
k
man
s
hip in the
di
s
pen
s
er
s
y
s
tem, for the full warranty period from the date of in
s
tallation in your home. If
warranty
s
ervice i
s
required during the warranty period, contact an authorized InSin
k
Erator
s
ervice agent to replace or repair the unit in your home at no co
s
t to you. If your di
s
pen
s
er i
s
replaced rather than repaired, the warranty on the new unit
s
hall be for the duration of the
remaining portion of the original di
s
pen
s
er’
s
warranty.
Note: Warranty is determined by unit
serial number and/or date of installation. Purchase or installation receipt may be required to
verify warranty status. When service is required, and for the location of your nearest factory
authorized service center, call toll free 1-800-558-5700.
The foregoing warranty doe
s
not apply to damage or inoperation re
s
ulting from accident,
alteration, mi
s
u
s
e, abu
s
e, improper in
s
tallation, in
s
tallation not in accordance with the
s
e
in
s
truction
s
or local electrical and/or plumbing code
s
. We do not a
ss
ume any re
s
pon
s
ibility for
con
s
equential damage. In
s
tall u
s
ing genuine InSin
k
Erator
®
manufactured component
s
only.
U
s
e of non InSin
k
Erator component
s
will void your warranty.
Some
s
tate
s
do not allow limitation
s
on how long an implied warranty la
s
t
s
, or the
exclu
s
ion or limitation
s
of incidental or con
s
equential damage
s
,
s
o the above limitation
s
or
exclu
s
ion may not apply to you. Thi
s
warranty give
s
you
s
pecific legal right
s
, and you may
al
s
o have other right
s
which vary from
s
tate to
s
tate.
This appliance must be grounded.
This instant hot water dispenser is equipped with a cord that
has a grounding conductor and a grounding pin. The plug must be connected to an appropriate
outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet
installed by a qualified electrician. Check with a qualified electrician or serviceman if you are in
doubt as to whether the instant hot water dispenser is properly grounded.
WARRANTY INFORMATION
Fire Hazard:
To minimize possibility of fire, DO NOT store flammable items such as
rags, paper or aerosol cans near the tank. DO NOT store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
An instant hot water dispenser, like any water heater, has a limited life and will eventually
fail. To avoid possible property damage, this instant hot water dispenser should be
regularly examined for leakage and replaced when necessary. A drain pan, plumbed to an
appropriate drain or outfitted with a leak detector, should be used in those applications
where any leakage could cause property damage.
Electric Shock Hazard:
To prevent electrical shock,
disconnect power before servicing unit. Use only a
properly grounded and polarized electric outlet.
Electric Shock Hazard:
Using an ungrounded or improperly connected appliance can
result in serious injury or death from electrical shock.