Emerson FB2100 Flow Computer Instruction Manual
D301783X012
March 2019
12
Installation
Table 2-1. Environmental Specifications
Specification
Configuration
Range
Aluminum Enclosure
Fiberglass Enclosure
Ambient
Temperature
No battery, C1D2
40°C to +80 °C
(-40 °F to +176 °F)
-35 °C to 80 °C
(-31 °F to 176 °F)
No Battery, C1D2,
Relay installed
-40 °C to 60 °C
(-40 °F to 140 °F)
-35 °C to 60 °C
(-31 °F to 140 °F)
Lead Acid Battery,
C1D2
-40 °C to 45 °C
(-40 °F to 113 °F)
-35 °C to 45 °C
(-31 °F to 113 °F)
ATEX/IEC Ex nA
No Battery
-25 °C to 55 °C
(-13 °F to 131 °F)
-25 °C to 55 °C
(-13 °F to 131 °F)
Humidity
5% to 95% non-condensing
Vibration
2g over 10 to 150 Hz; 1g over 150 to 200 Hz
2.3
Required Tools
Certain tools and equipment are required for installing and servicing the flow computer.
Table 2-2. Required Tools
Tool
Use
Torque wrench
For bolting/mounting the flow computer
2.5 mm hexagonal wrench
For manipulating rotation set screw
High-wattage soldering iron and solder
For tinning ground connection wire
#1 Phillips-head screwdriver
For screws on HMI module
#2 Phillips-head screwdriver
For screws on other modules and boards
#3 Phillips-head screwdriver
For optional aluminum enclosure clamps
1/8 inch flat-head screwdriver
For 5.08 mm pitch terminal block connections
7/32 inch flat-head screwdriver
For installing external solar controller
Utility knife
For installing external solar controller
Wire cutters
For installing external solar controller
Wire strippers
For installing external solar controller
Laptop PC running Field Tools with FBxConnect
configuration software
For software configuration
Содержание FB2100
Страница 62: ...Emerson FB2100 Flow Computer Instruction Manual D301783X012 March 2019 58 Installation ...
Страница 76: ...Emerson FB2100 Flow Computer Instruction Manual D301783X012 March 2019 72 I O Configuration and Wiring ...
Страница 114: ...Emerson FB2100 Flow Computer Instruction Manual D301783X012 March 2019 Index 111 ...
Страница 115: ...Emerson FB2100 Flow Computer Instruction Manual D301783X012 March 2019 106 ATEX Non Sparking Zone 2 Certifications ...