Emerson FB2100 Flow Computer Instruction Manual
D301783X012
March 2019
Installation
11
Section 2:
Installation
This section covers the following topics:
▪
Hazardous Locations
▪
Environmental Specifications
▪
Required Tools
▪
Site Considerations
▪
General Wiring Guidelines
▪
Grounding
▪
Opening/Closing the Enclosure
▪
Mounting the Enclosure
▪
Power Modes
▪
Connecting Power
▪
Installing the Optional 30W Solar Panel
▪
Adjusting the Optional Solar Panel
▪
Connecting Communications Ports
▪
Door Contact Terminal
The flow computer ships from the factory fully assembled, except for the optional solar panel
assembly.
2.1
Hazardous Locations
The housing for the FB2100 is an explosion-proof case designed to operate in hazardous locations.
For North America the FB2100 has certifications for Class I Division 2 (Groups A, B, C & D) non-
incendive, and non-hazardous locations only.
Appendix A
contains special information for Class I
Division 2 installations.
For other world areas the FB2100 has ATEX and IEC Ex certifications for Ex nA Zone 2 non-sparking
installations and non-hazardous locations only. See
Appendix B
for more information.
All certifications are listed on the data plate located on the top of the device.
2.2
Environmental Specifications
This section summarizes the environmental specifications for the device. For full details, refer to
the product data sheet
FB2100 Flow Computer
(D301791X012)
.
Содержание FB2100
Страница 62: ...Emerson FB2100 Flow Computer Instruction Manual D301783X012 March 2019 58 Installation ...
Страница 76: ...Emerson FB2100 Flow Computer Instruction Manual D301783X012 March 2019 72 I O Configuration and Wiring ...
Страница 114: ...Emerson FB2100 Flow Computer Instruction Manual D301783X012 March 2019 Index 111 ...
Страница 115: ...Emerson FB2100 Flow Computer Instruction Manual D301783X012 March 2019 106 ATEX Non Sparking Zone 2 Certifications ...