TM
8
Installation Operation & Maintenance manual ELQ
DOC.55.EDN Rev: E
October 2012
ok!
ok!
3
MOUNtING tHE ELQ UNIt ON A VALVE
Remove handle nut, handle, lockwasher, etc. from
valve if required. Check position of valve.
There are two possibilities for mounting the ELQ unit:
• Direct mounting.
• Bracket mounting.
3.0.2 Bracket mounting
• Mount bracket and adaptor on valve.
• Place insert in bottom flange at actuator.
3.0.1 Direct mounting
• Place insert in bottom flange of actuator.
3.0.3 Normal valve rotation
Valves are manufactured so that they oper
-
ate in only one 90 degree segment. The
actuator should be mounted for counterclock-
wise rotation to open and clockwise to close
the valve.