6.2
Connecting the power supply.
• Remove the front cover.
• Mount cable gland in the front cover.
• Insert power cable through cable gland and front
cover.
• Connect power cable to power board (see fig.
6.1.1 / 6.2.1).
• Mount front cover in desired position (see fig.
6.2.1).
• Install cable gland and mount the cover
6.3
Main fuse replacement
table 6.2 Internal main fuse ELQ-actuators
Actuator
Fuse type Dim.
ELQ 100/200/300/500/800
T 10 A
ø 5 x 20 mm
6.2.1 Connect power cable to power board
For pipe connection see fig. 6.2.2.
6.2.2 Pipe connection
6.3.1 Main fuse
Important
•
After adjustments always mount the cover to
the housing.
•
Take care that the cover seal is in place to
comply to dust and water tightness according