TM
7
Installation Operation & Maintenance manual ELQ
DOC.55.EDN Rev: E
October 2012
Motor switch
Open
Motor switch
Close
Limit switch
Open
Limit switch
Close
2.4
Electronic control unit
2.4.1 Layout of basic print
Warning
The electronic parts of the ELQ-actuator or the options can be damaged by a discharge of static elec
-
tricity. Before you start touch a grounded metal surface to become static free.
Main Fuse
Connector for:
Supply
Motor
Heater
Connector for:
Local Control Sta
-
tion (option)
Jumpers for Torque
adjustment § 4.2
Connector for:
- Positioner (option)
- Communication card (option)
- Speed control (option)
(stacked max. 2 options)
Potmeter connector
for: Position Trans
-
mitter (option)
Potmeter connec
-
tor for :
Potentiometer
(option)
Limit switch
assembly
Potentiometer
(option)
Fuse
6 pole connector
for Extra Switches
(option)
Main connector
Connector limit switches
Connector for:
Motor switches
Connector for:
Position Transmitter (option)
Connector for:
Status Module (option)
6 pole connector for
Status Module option