1592026260 IEV22-24D GB r.1.0 21.02.2019 IEV 10/60
Other parameters involved on visualization/configuration
Ec41
Unit of measure (°C / bar ÷ °F / psi)
Ec42
Pressure measurement
(0=relative, 1= absolute)
Ec45
Operning percentage visualization
(0=no, 1=yes)
3.4
Viewing the measured or calculated variables
Press the
keys to view the values of the following measured and calculated variables
concerning valve 1 or 2:
-
Superheating set point (SHC / SHH)
-
Superheating value (SH)
-
Valve opening (OPEn)
-
Suction temperature (SCt1)
-
Evaporation pressure (LP1)
-
Evaporation temperature (tP1)
-
Operation mode (Cool / HEAt)
-
Adjustment method (Man
–
AUto)
Press the
key to select whether to view the variables of probe 1 or probe 2.