Use appropriate torque values to reinstall the shaft nut and to avoid equipment damage or
inaccurate turbine meter operation.
Important
The shaft nut can only be reused up to five times. Replace as needed.
Torque requirements for shaft nut reinstallation
Table 9-1:
Turbine meter size
Torque requirement
3
7.9 n-m (70 in-lbs)
4
11.3 n-m (100 in-lbs)
6
67.7-81.3 n-m (50-60 ft-lbs)
8
67.7-81.3 n-m (50-60 ft-lbs)
10
81.3-95 n-m (60-70 ft-lbs)
12
95-122 n-m (70-90 ft-lbs)
16
108-135 n-m(80-100 ft-lbs)
18
108-135 n-m (80-100 ft-lbs)
20
108-135 n-m (80-100 ft-lbs)
24
108-135 n-m (80-100 ft-lbs)
9.4.1
Assemble internal meter housing components -NPS 3
through 24
1.
Install the upstream hanger assembly in the inlet side. Secure the upstream hanger
by tapping the hanger assembly with a plastic hammer.
Upstream hanger assembly installation
Figure 9-8:
Planned maintenance
User manual
77
Содержание daniel 1500 series
Страница 1: ...User manual P N 3 9008 515 Rev D July 2016 Daniel Series 1500 Liquid Turbine Meter NPS 3 through 24 ...
Страница 8: ......
Страница 12: ...Plan 2 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 64: ...Prepare the turbine meter for use 54 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 66: ...Install 56 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 72: ...Installation procedure 62 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 74: ...Testing 64 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 75: ...Part III Operate Operate User manual 65 ...
Страница 76: ...Operate 66 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 80: ...Maintain 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 101: ...Decommission the turbine meter User manual 91 ...
Страница 102: ...Decommission the turbine meter 92 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 103: ...Decommission the turbine meter User manual 93 ...