2.
Install the housing on the turbine meter body. Use four screws with a torque value of
55 lbs-ft. (Capacity to be installed: each at 90º).
3.
Insert the pickoffs and anti-rotation bracket.
4.
Install the conduit.
5.
Install the internal and external grounding cable to lug.
6.
Tighten the terminal blocks socket screws to the bracket plate.
7.
Install the pickoff cables and opt out the signal connections to the terminal blocks.
8.
Tighten the socket screws from the plate to the housing.
9.
Install the solid end cap.
10.
Install the security seals.
11.
Install the security seal wire.
9.7
Replace the preamplifier
1.
Disconnect all power to the turbine meter.
2.
Remove cover of the RME.
3.
Loosen screws of preamplifier bracket and lift out of the enclosure.
4.
Disconnect terminal connects at TB1, TB2, and TB3.
5.
Loosen screws of preamplifier and lift out.
6.
Mount the replacement preamplifier board in its original position and secure using
screws.
7.
Attach electrical output wiring from both pickoffs to terminal connection TB2 and
TB3.
8.
Attach electrical output wiring from electrical accessories (conduit wiring) to
terminal connection TB1, number 3 for channel A, and number 5 for channel B.
9.
Secure all electrical wiring.
10.
Secure screws of preamplifier bracket in to the enclosure.
11.
Return cover and secure.
Planned maintenance
User manual
83
Содержание daniel 1500 series
Страница 1: ...User manual P N 3 9008 515 Rev D July 2016 Daniel Series 1500 Liquid Turbine Meter NPS 3 through 24 ...
Страница 8: ......
Страница 12: ...Plan 2 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 64: ...Prepare the turbine meter for use 54 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 66: ...Install 56 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 72: ...Installation procedure 62 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 74: ...Testing 64 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 75: ...Part III Operate Operate User manual 65 ...
Страница 76: ...Operate 66 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 80: ...Maintain 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 101: ...Decommission the turbine meter User manual 91 ...
Страница 102: ...Decommission the turbine meter 92 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 103: ...Decommission the turbine meter User manual 93 ...