Damcos KC Actuators: Adjustment of the DPI
Quick Installation Guide
February 2020
QIG 8000-81-003 Ed 01
21
12.
Operate the hand pump
and observe that the
actuator spindle moves
in. When in position ‘in’,
the actuator is 'Open'.
Check for ‘Open’ sound
signal (or Ω display shows
approx. 1400/7000).
13.
The DPI is now correctly adjusted with regard to the ‘Open’ and ‘Closed’ signals.
Note!
For DPI-E the multimeter should thus send a sound signal on terminal 7 + 8 when the actuator is in
position open, and on 9 + 10 when in position closed. Between the two positions the sound signal
must be off.
For DPI-C the value should be Ω 300/1500 for ‘Closed’ and Ω 1400/7000 for ‘Open’.
14.
Disconnect the multimeter.
15.
Fasten the locking screw
(b) and mount the screw
(a).
16.
Leave the actuator in
position ‘Closed’ = actua-
tor spindle is max. out.
Содержание Damcos KC 125
Страница 4: ...Quick Installation Guide Table of Contents RM 8000 100 01 Ed 01 February 2020 2 ...
Страница 6: ...Quick Installation Guide General Information QIG 8000 81 003 Ed 01 February 2020 4 ...
Страница 7: ...Quick Installation Guide February 2020 QIG 8000 81 003 Ed 01 5 Normal Installation ...
Страница 8: ...Quick Installation Guide QIG 8000 81 003 Ed 01 February 2020 6 ...
Страница 24: ...Quick Installation Guide Damcos KC Actuators Adjustment of the DPI QIG 8000 81 003 Ed 01 February 2020 22 ...
Страница 26: ...Quick Installation Guide Determine the Configured Stroke QIG 8000 81 003 Ed 01 February 2020 24 ...
Страница 28: ...Quick Installation Guide Trouble Shooting QIG 8000 81 003 Ed 01 February 2020 26 ...
Страница 30: ...Quick Installation Guide QIG 8000 81 003 Ed 01 February 2020 28 ...
Страница 40: ...Quick Installation Guide QIG 8000 81 003 Ed 01 February 2020 38 ...
Страница 41: ...Quick Installation Guide February 2020 QIG 8000 81 003 Ed 01 39 Appendix A ...
Страница 42: ...Quick Installation Guide QIG 8000 81 003 Ed 01 February 2020 40 ...
Страница 45: ......