background image

3

safety precautions

Proper handling, storage, installation, 
maintenance and operation is essential to the 
safe and reliable functioning of any pressure 
relief product�
Precautionary statements in the form of 
warnings, cautions and notes are used 
throughout this instruction to emphasize 
important and critical factors where applicable�

examples:

Warning

An operating procedure or practice which, if not 
observed strictly, may result in injury to personnel 
or loss of life.

CauTion

An operating procedure or practice which, if not 
observed strictly, may result in damage to or 
destruction of equipment.

Crosby

 STylE JOS-E, JBS-E, JlT*-JBS-E, JlT*-JOS-E ValVES

InstallatIon and MaIntenance InstructIons

FIguRE 2 - Sample nameplates

ordering spare parts

When ordering spare parts, the valve size, style 
and assembly number and/or serial number 
should be given together with set pressure, part 
name and reference number from page 2� The 
valve assembly number is shown on the valve 
nameplate as, 'Shop Number'� Spare parts may 
be ordered from any Emerson regional sales 
office or representative�

all personnel working with Emerson products 
should be trained adequately and thoroughly 
familiar with the contents of the appropriate 
instruction manual(s)�

Emerson cannot evaluate all conditions in 
which the products may be used�

However, Emerson offers the following general 
safety suggestions:
• Never subject valves to sharp impact loads. 

Rough handling (striking, bumping, dropping, 
etc�) may alter the pressure setting, deform 
valve parts and affect seat tightness and valve 
performance adversely� Striking a valve which 
is under pressure can cause premature 
actuation�

These precautionary statements are by no 
means exhaustive�
Emerson cannot be expected to know, evaluate 
and advise customers of all the possible 
applications and operating conditions for 
its products or of the possible hazardous 
consequences which may result from the 
misapplication or misuse of such products�

Consequently, the improper handling, 
storage, installation, use or maintenance 
of any Emerson product by a non Emerson 
employee may void any Emerson guarantees or 
warranties with respect to such product�

Sample nameplate after 2014

Restricted lift nameplate

• When moving a valve, never use the lifting 

lever to lift the valve�

• Always lower the system pressure to the 

pressure level specified in the instruction 
before making any adjustment to the valve� 
Furthermore, always install a proper test rod 
to gag an installed valve before making any 
ring adjustments on the valve�

• Ear and eye protection should be used when 

working on a valve which has pressure�

• Never stand in front of the discharge outlet 

of a pressure relief valve which is under 
pressure�

• Always stand to the side of and at a safe 

distance from the valve discharge and use 
extreme care when observing a valve for 
leakage�

The above precautions and suggestions are 
by no means exhaustive and the user should 
always approach and use any pressure relief 
valve with great care�

Operation, Installation and Safety Instructions 
are available at Emerson�com/FinalControl or 
from your local Emerson regional sales office 
or representative�

Содержание Crosby JBS-E Series

Страница 1: ...hould use only parts manufactured by Emerson Call your nearest Emerson regional sales office or representative for a service engineer should you wish assistance with your field needs Table of Contents 1 Introduction 4 2 Storage and handling 4 3 Installation 4 4 Hydrostatic pressure tests 5 5 Setting testing and adjustments 6 6 Valve maintenance 10 7 Style variations 21 8 Service records 21 9 Spare...

Страница 2: ...art name Notes Notes 1 Consumable spare parts valve parts which should be replaced as part of any disassembly and discs and disc inserts which must be replaced if seats are damaged 2 Repair spare parts valve parts exposed to wear and or corrosion during normal operation They are in fluid flow paths and may require replacement as part of any repair 16 Spindle 3 17 Spindle cotter pin 1 L T orifice 1...

Страница 3: ...he pressure setting deform valve parts and affect seat tightness and valve performance adversely Striking a valve which is under pressure can cause premature actuation These precautionary statements are by no means exhaustive Emerson cannot be expected to know evaluate and advise customers of all the possible applications and operating conditions for its products or of the possible hazardous conse...

Страница 4: ...ned specifically for liquid service The JLT E features patented contoured liquid trim in a standard JOS E JBS E envelope 3 3 Inlet piping Pressure relief valves should be mounted vertically in an upright position either directly on a nozzle from the pressure vessel or on a short connecting fitting that provides direct and unobstructed flow between the vessel and the valve Installing a pressure rel...

Страница 5: ...flange be installed in its place This practice precludes the possibility of any damage to the pressure relief valve Bent spindles and damaged valve seats are problems that can be caused by improper hydrostatic test procedures Blank flanges must be removed and the pressure relief valve reinstalled before the vessel is placed in service When the hydrostatic test must be performed with the valve in p...

Страница 6: ...ection 5 8 and specifically in Section 5 8 1 For valves with set points in excess of 500 psig it is recommended that when testing on a low volume test bench the lift be restricted temporarily by use of a gag or other suitable device However it is good practice to inspect the valve prior to installation This inspection determines any damage which may have occurred due to rough handling in transit o...

Страница 7: ...r of notches moved so that the ring can be returned to its proper position following testing Moving the notches on the nozzle ring to the left will lower the nozzle ring Replace the nozzle ring set screw before each set pressure test The set screw must engage one of the ring notches being careful that it does not bear on the top of a tooth 5 8 2 Remove the cap or lifting lever following the instru...

Страница 8: ...set pressure correction factors at ambient temperature Set pressure psig Increase in spring set pressure 5 9 5 Style JLT The Style JLT in the P Q R and T orifice sizes is preset at the factory and cannot be adjusted externally in the field since the special contoured skirt on the disc holder prevents engagement of the set screw with the nozzle ring As a result the nozzle ring is not slotted and is...

Страница 9: ...e with 0 035 inch wall The tube end is cut square and smooth is parallel to and inch below the surface of the water A snap on type test clamp shown in Figure 5 is available Procedure With the valve mounted vertically the leakage rate in bubbles per minute shall be determined with pressure at the pressure relief valve inlet raised up to and held at 90 percent of the set pressure or cold differentia...

Страница 10: ... less than ten minutes Allowable leakage rate The maximum allowable leakage rate should not exceed 10 cubic centimeters per hour per inch of diameter of nominal valve inlet size For nominal valve sizes of 1 inch or less the leakage rate shall not exceed 10 cubic centimeters per hour For soft seated valves there shall be no leakage for one minute Soft seated valves For exceptional seat tightness an...

Страница 11: ...rts may be cleaned by wire brushing provided the brushes used do not damage nor contaminate the base metals Only clean stainless steel brushes should be used on stainless steel components The internal parts such as the guide disc holder disc insert nozzle ring and spindle should be cleaned by immersion in a commercial high alkaline detergent Guiding surfaces on the disc holder and guide may be pol...

Страница 12: ...s have been damaged badly by dirt or scale lapping the seating surfaces should restore them to their original condition Never lap the disc insert against the nozzle Lap each part separately against a cast iron lapping block of the proper size These blocks hold the lapping compound in their surface pores and must be recharged frequently Lap the block against the seat Never rotate the block continuo...

Страница 13: ...be tight nor will it operate properly unless all parts are machined correctly The most satisfactory way to machine a nozzle is to remove it from the valve body However it may also be machined while assembled within the valve body In any event it is vitally important that the seating surfaces run absolutely true before machining Figure 10 Nozzle seat critical dimensions Minimum face to seat dim ref...

Страница 14: ...disc holder 5 and guide 15 by sliding the guide over the disc holder Note the guide for D and E orifice valves protrudes up into the valve bonnet 6 6 6 Install the two guide gaskets 28 one above and one below the guide Note when assembling bellows valves the bellows flange eliminates the need for a bottom guide gasket 6 6 7 While holding the top of the disc holder install the guide into the body A...

Страница 15: ...asure the valve lift Install the limit spacer see Figure 13 with the chamfer down and reassemble the valve as described in Steps 6 6 1 through 6 6 10 Note install bellows to disc holder for JBS F orifice valve then install spacer Measure the lift of the valve and compare it with the required lift as given on the restricted lift nameplate with tolerance 020 0 020 0 50 mm 0 50 mm Based on the result...

Страница 16: ...67 11408750 0 051 F 1 4 11408566 0 099 11408577 0 078 11408588 0 058 F 5 7 11408566 0 099 11408577 0 078 11408588 0 058 G 11408820 0 120 11408821 0 093 11408823 0 066 H 11408831 0 141 11408832 0 108 11408834 0 075 J 11408844 0 172 11408845 0 130 11408847 0 087 K 11408859 0 204 11408860 0 153 11408861 0 103 L 1 4 11408390 0 248 11408391 0 185 11408392 0 122 L 5 6 11408405 0 261 11408406 0 198 11408...

Страница 17: ...1408577 0 078 11408519 0 054 F 5 7 11408691 0 105 11408657 0 079 11408623 0 054 G 11408816 0 126 11408821 0 093 11408817 0 061 H 11408826 0 151 11408832 0 108 11408827 0 069 J 11408837 0 186 11408838 0 133 11408540 0 081 K 11408851 0 217 11408860 0 153 11408852 0 092 L 1 4 11408865 0 268 11408866 0 189 11408867 0 111 L 5 6 11408397 0 281 11408398 0 202 11408399 0 124 M 11408413 0 296 11408414 0 20...

Страница 18: ...spacer of 70 of full capacity in Table 10 11408478 Nameplate restricted lift 1 243 70 0 870 inches Nameplate capacity 374 860 lbs hr 70 262 402 lbs hr Case 2 Capacity required 165 000 lbs hr Selection 2 Maximum not to exceed rated Nameplate Capacity 110 of capacity required 181 500 lbs hr Required capacity of full capacity 165 000 374 860 44 Required lift 44 1 243 inches 0 547 inches Choose two sp...

Страница 19: ... ring soft seat or vice versa Type D Install the cap gasket on the bonnet Screw the spindle nut onto the spindle Place the dog in the cap and install the dog shaft so that the dog is horizontal and the square on the end of the dog shaft has a corner on top With the dog shaft in the position above scribe a horizontal line on the end of the dog shaft This line must be horizontal when the lifting gea...

Страница 20: ...otter pin Cotter pin Cotter pin Pin Pin Spindle Spindle nut Spindle nut Spindle Valve spindle Spindle Test rod Spindle Adjusting bolt Adjusting bolt nut Dog shaft Dog shaft Dog shaft gasket Dog shaft Dog Dog Lockwasher Lever nut Lever nut Lever nut lockwasher Lever Lever Packing gland Packing Packing gland sleeve Packing gland nut Forked lever Lever Cap plug Cap plug gasket Cap top gasket Cap gask...

Страница 21: ...parts the valve shop number assembly number or serial number should be given together with set pressure part name and item number valve size and style On the valve nameplate the valve assembly number is shown as shop number Spare parts may be ordered from any Emerson regional sales office or representative 10 Trouble shooting pressure relief valves Troubles encountered with pressure relief valves ...

Страница 22: ...e of the product The advice of a qualified engineer should be sought prior to any use of the product Any installation maintenance adjustment repair or test performed on the product must be done in accordance with the requirements of all applicable codes and standards The information specifications and technical data the Specifications contained in this document are subject to change without notice...

Отзывы: