![Emerson AVENTICS PM1 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/emerson/aventics-pm1/aventics-pm1_operating-instructions-manual_104371009.webp)
3 Scope of delivery
The scope of delivery includes:
• 1x electromechanical pressure switch PM1 with 3 m or 7 m cable
• 2x mounting screws, for flange version
• O-ring, for flange version
• Operating instructions
4 About This Product
4.1 Product description
The PM1 is used to open or close an electrical contact when a pre-set pressure
range is reached.
4.2 Performance specifications
An appropriate medium is applied to the PM1 at the G1/4 connection or on the
flange. A bellow actuates a microswitch (change-over switch) via a mechanism
once the preset switching pressure is reached.
The contact switches (see
• if the pressure increases from 1-2 to 1-3,
if the pressure decreases from 1-3 to 1-2.
• if the underpressure increases from 1-3 to 1-2,
if the underpressure decreases from 1-2 to 1-3
4.3 Overview of PM1 pressure switch, ATEX certified
4.3.1 Pneumatic flange connection
5
30
48,5
68
ca.74
5
3m / 7m
2
5
20
10
30
Ø5,2
1,15
Ø8
1
2
3
Fig. 1: Pneumatic flange connection
1 O-ring ø 5x1.5 (included in scope of
delivery)
2 Adjustment screw for fine adjust-
ment, self-holding
3 Cylinder screw M5x30 ISO 1207 (2x);
MA = 2.5+0.5 Nm (included in scope
of delivery)
4.3.2 Pneumatic connection, internal thread G1/4
G1/4"
5
30
48,5
Ø9,6
12
+2,0 -0,5
73
ca.79
3m / 7m
2
5
20
30
15
Ø5,2
1
2
Fig. 2: Pneumatic connection, internal thread G1/4
1 Connection G1/4, MA = 12+0.1 Nm
2 Adjustment screw for fine adjust-
ment, self-holding
For material numbers, please refer to the online catalog.
4.4 Product identification
u
Observe the product information on the product and packaging.
The ATEX information can be found on the back of the product.
4.5 Identification on the name plate
1
3
2
7290
Made in Germany
20W19
ZZZZ
Set 1,5 b ....
R412XXXXXX - PM1
pe
0,2 - 16bar
U
max
30 V DC / 250 V AC
I
max
3 A
S
max
90 W / 750 VA
AVENTICS GmbH, Ulmer Straße 4, 30880 Laatzen, Germany
1
2
3 4
5
6
7
8
9
10
11
12
13
14
15
16
Fig. 3: Name plate
1 Internal factory designation
2 Country of manufacture
3 EAC mark
4 Specialist marking
5 CE mark
6 Material number
7 Operating pressure range
8 Max. permissible voltage
9 Max. current consumption
10 Max. power consumption
11 Serial number
12 Manufacturer's address
13 Date code*
14 Customer-specific switching pressure
15 Wiring diagram
16 Manufacturer logo
*)
The first four digits of the 7-digit date code show the year and the last two show
the week.
II 3G Ex nc IIC T4 GC
II 3D Ex tc IIIC T135 °C Dc
-20 °C ≤ T amb ≤ 80 °C
Cert-No. EPS 21 ATEX 1 188 X
BETRIEBSANLEITUNG BEACHTEN
OBSERVE OPERATING INSTRUCTIONS
Fig. 4: Back side name plate
AVENTICS™
PM1 | R412018626-BAL-001-AI | English
9
Содержание AVENTICS PM1
Страница 7: ...AVENTICS PM1 R412018626 BAL 001 AI Deutsch 7 ...
Страница 12: ...AVENTICS PM1 R412018626 BAL 001 AI English 12 ...
Страница 18: ...AVENTICS PM1 R412018626 BAL 001 AI Français 18 ...
Страница 24: ...AVENTICS PM1 R412018626 BAL 001 AI Italiano 24 ...
Страница 30: ...AVENTICS PM1 R412018626 BAL 001 AI Español 30 ...
Страница 35: ...AVENTICS PM1 R412018626 BAL 001 AI Svenska 35 ...
Страница 41: ...AVENTICS PM1 R412018626 BAL 001 AI Русский 41 ...