Safety Notes
ATCA-F140 Installation and Use (6806800M67H)
125
Injuries or Short Circuits
Blade or power supply In case the ORing diodes of the blade fail, the blade may trigger a short
circuit between input line A and input line B so that line A remains powered even if it is
disconnected from the power supply circuit (and vice versa). To avoid damage or injuries,
always check that there is no more voltage on the line that has been disconnected before
continuing your work.
Configuration Switches/Jumpers
Product
Malfunction
Switches marked as “Reserved” might carry production-related functions and can cause the
product to malfunction if their setting is changed.
Do not change settings of switches marked as “reserved”.
Product
Damage
Setting/resetting the switches during operation can cause damage to the product.
Check and change switch settings before you install the product.
Product
Damage
Too much force may damage the reset switch.
Use minimal force when pressing the reset switch.