EES-101 Series Ultrasonic Flowmeter
Revision: 3.0.1
Page 7 of 65
1.2
Wire Connecting
1.2.1
Power supply option
Customers should pay special attention to
the specified
power supply
options
when wiring.
Factory standard power supply is 10~36VDC/1A max.
To ensure the transmitter can work normally, please pay attention to the followings when wiring:
Ensure that power connections are made in accordance with the specifications shown on the transmitter.
1.2.2
Transmitter Wiring
Once the electronics enclosure has been installed, the
f
lowmeter wiring can be connected.
Once you open
the case, you will find the transmitter interfaces labels from left to right as follows:
Power supply, Relay output, OCT Output, Upstream transducer, Downstream transducer, 4-20mA, RS485
interface.
Refer to the below diagram for specific connection:
1.2.3
Lengthened Cable Method
Standard cable length of sensor is 9 meters
(~30 feet)
; it can be lengthened to be 300 meters according to the
actual need for fluid measurement.
Please contact Emergent Energy for specific applications where longer cables
will be needed.
Red Bushing
Flow
DC+ DC-
GE
DC 10 - 36V
E UP+ UP-
E DN+ DN-
TRANSDUCER
I+
I-
4-20mA
Blue Bushing
Being tested pipe
Black
Red
Shield
Pipe Straps
Upstream Transducer
Downstream Transducer
OCT+ OCT-
OCT
OUT
RL+ RL-
RELAY
Shield
Red
Black
Up
-S
tr
eam
Down
-S
tr
eam
10~36VDC
A
B
RS485